39 / 73 page ![]() 2004 May 17 39 Philips Semiconductors Product specification 80 × 128 pixels matrix LCD driver PCF8811 13.10.1 BASIC COMMAND SET The VLCD at T = TCUT in the basic command set is determined by the conversion in the ROM look-up table with the programmed values of VPR[5:0] and VOFF[2:0]. It can, additionally, be adjusted with the VLCD offset pads VOS[4:0] to obtain the optimum optical performance. Instead of using the VLCD offset pads (VOP[4:0]) the VLCD can be adjusted with the module maker calibration setting MMVOPCAL[4:0]; see Chapter 22. (4) Where: • T CUT is a reference temperature; see Section 13.11 • a is a fixed constant value; see Table 22 • b is a fixed constant value; see Table 22 • V OP[7:0] is the result of the conversion table • V OS[4:0]/MMVOPCAL[4:0] is the value of the offset VLCD offset pads or the value stored in the OTP cells. Table 22 Parameters of VLCD for the basic and extended command set 13.10.2 EXTENDED COMMAND SET The VLCD at T = TCUT can be calculated with equation (5). In the extended command set VPR[7:0] is the same value as VOP[7:0]. It can additionally be adjusted with the VLCD offset pads VOS[4:0] to obtain the optimum optical performance. Instead of using the VLCD offset pads (VOP[4:0]) the VLCD can be adjusted with the module maker calibration setting MMVOPCAL[4:0]; see Chapter 22. (5) Where: • T CUT is a reference temperature (see Section 13.11) • a is a fixed constant value (see Table 22) • b is a fixed constant value (see Table 22) • V PR[7:0] is the programmed VOP value • V OS[4:0]/MMVOPCAL[4:0] is the value of the offset VLCD offset pads or the value stored in the OTP cells. As the programming range for the internally generated VLCD allows values above the maximum allowed VLCD (9 V) the user has to ensure while setting the VPR register and selecting the Temperature Compensation (TC), that under all conditions and including all tolerances the VLCD remains below 9.0 V. This is valid for the two different command sets. SYMBOL VALUE UNIT TCUT 40 °C b 0.03 V a3 V V LCD TT CUT = () aV OS [4:0] V OP [7:0] + () b × + = V LCD TT CUT = () aV OS [4:0] V PR [7:0] + () b × + = |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |