| 数据搜索系统,热门电子元器件搜索 |
|
MPF5024AMBA0ES 数据表(PDF) 45 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
MPF5024AMBA0ES 数据表(HTML) 45 Page - NXP Semiconductors |
|
45 / 93 page ![]() NXP Semiconductors PF5024 Power management integrated circuit (PMIC) for high performance applications PF5024 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2020. All rights reserved. Product data sheet Rev. 1 — 15 April 2020 45 / 93 14.9.11 SDA and SCL (I2C bus) Communication with the PF5024 is done through I2C and it supports high-speed operation mode with up to 3.4 MHz operation. SDA and SCL are pulled up to VDDIO with 1.5 kΩ resistors. The PF5024 is designed to operate as a slave device during I2C communication. The default I2C device address is set by the OTP_I2C_ADD[2:0]. Table 33. I2C address configuration OTP_I2C_ADD[2:0] Device address 000 0x08 001 0x09 010 0x0A 011 0x0B 100 0x0C 101 0x0D 110 0x0E 111 0x0F See http://www.nxp.com/documents/user_manual/UM10204.pdf for detailed information on the digital I2C communication protocol implementation. During an I2C transaction, the communication will latch after the 8th bit sent. If the data sent is not a multiple of 8 bit, any word with less than 8 bits will be ignored. If only 7 bits are sent, no data is written and the logic will not provide an ACK bit to the MCU. From an IC level, a wrong I2C command can create a system level safety issue. For example, though the MCU may have intended to set a given regulator’s output to 1.0 V, it may be erroneously registered as 1.1 V due to noise in the bus. To prevent a wrong I2C configuration, various protective mechanisms are implemented. 14.9.11.1 I2C CRC verification When this feature is enabled, a selectable CRC verification is performed on each I2C transaction. • When OTP_I2C_CRC_EN = 0, the CRC verification mechanism is disabled. • When OTP_I2C_CRC_EN = 1, the CRC verification mechanism is enabled. After each I2C transaction, the device calculates the corresponding CRC byte to ensure the configuration command has not been corrupted. When a CRC fault is detected, the PF5024 ignores the erroneous configuration command and triggers a CRC_I interrupt asserting the INTB pin, provided the interrupt is not masked. The PF5024 implements a CRC-8-SAE, per the SAE J1850 specification. • Polynomial = 0x11D • Initial value = 0xFF |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |