25 / 44 page ![]() Data Sheet AD9959 Rev. C | Page 25 of 44 LINEAR SWEEP MODE Linear sweep mode enables the user to sweep frequency, phase, or amplitude from a starting point (S0) to an endpoint (E0). The purpose of linear sweep mode is to provide better band- width containment compared to direct modulation by replacing greater instantaneous changes with more gradual, user-defined changes between S0 and E0. In linear sweep mode, S0 is loaded into the Channel Word 0 register (S0 is represented by one of three registers: Register 0x04, Register 0x05, or Register 0x06, depending on the type of sweep) and E0 is always loaded into Channel Word 1 (Register 0x0A). If E0 is configured for frequency sweep, the resolution is 32 bits, phase sweep is 14 bits, and amplitude sweep is 10 bits. When sweeping phase or amplitude, the word value must be MSB aligned in the Channel Word 1 register. The unused bits are don’t care bits. The profile pins are used to trigger and control the direction of the linear sweep for frequency, phase, and amplitude. All channels can be programmed separately for a linear sweep. In linear sweep mode, Profile Pin P0 is dedicated to Channel 0. Profile Pin P1 is dedicated to Channel 1, and so on. The AD9959 has the ability to ramp up or ramp down (RU/RD) the output amplitude (using the 10-bit output scalar) before and after a linear sweep. If the RU/RD feature is desired, unused profile pins or unused SDIO_1/SDIO_2/SDIO_3 pins can be configured for the RU/RD operation. To enable linear sweep mode for a particular channel, the AFP select bits (CFR[23:22]), the modulation level bits (FR1[9:8]), and the linear sweep enable bit (CFR[14]) are programmed. The AFP select bits determine the type of linear sweep to be performed. The modulation level bits must be set to 00 (two- level) for that specific channel (see Table 19 and Table 20) Table 19. Linear Sweep Parameter to Sweep AFP Select (CFR[23:22]) Linear Sweep Enable (CFR[14]) Description 00 1 N/A 01 1 Amplitude sweep 10 1 Frequency sweep 11 1 Phase sweep Table 20. Modulation Level Assignments Modulation Level (FR1[9:8]) Description 00 (Required in Linear Sweep) Two-level modulation 01 Four-level modulation 10 Eight-level modulation 11 16-level modulation Setting the Slope of the Linear Sweep The slope of the linear sweep is set by the intermediate step size (delta-tuning word) between S0 and E0 and the time spent (sweep ramp rate word) at each step. The resolution of the delta-tuning word is 32 bits for frequency, 14 bits for phase, and 10 bits for amplitude. The resolution for the delta ramp rate word is eight bits. In linear sweep, each channel is assigned a rising delta word (RDW, Register 0x08) and a rising sweep ramp rate word (RSRR, Register 0x07). These settings apply when sweeping up toward E0. The falling delta word (FDW, Register 0x09) and falling sweep ramp rate (FSRR, Register 0x07) apply when sweeping down toward S0. Figure 36 displays a linear sweep up and then down using a profile pin. Note that the linear sweep no-dwell bit is disabled; otherwise, the sweep accumulator returns to 0 upon reaching E0. RDW RSRR FSRR ∆f,p,a FDW TIME S0 E0 PROFILE PIN ∆f,p,a ∆t ∆t Figure 36. Linear Sweep Parameters For a piecemeal or a nonlinear transition between S0 and E0, the delta-tuning words and ramp rate words can be repro- grammed during the transition to produce the desired response. The formulas for calculating the step size of RDW or FDW for delta frequency, delta phase, or delta amplitude are as follows: SYSCLK RDW f 32 2 (Hz) 360 2 14 RDW ΔΦ 1024 2 10 RDW a (DAC full-scale current) The formula for calculating delta time from RSRR or FSRR is CLK SYNC RSRR t _ / 1 At 500 MSPS operation (SYNC_CLK = 125 MHz), the maxi- mum time interval between steps is 1/125 MHz × 256 = 2.048 μs. The minimum time interval is (1/125 MHz) × 1 = 8.0 ns. The sweep ramp rate block (timer) consists of a loadable 8-bit down counter that continuously counts down from the loaded value to 1. When the ramp rate timer equals 1, the proper ramp rate value is loaded and the counter begins counting down to 1 again. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |