62 / 72 page ![]() Document Feedback AS7331 Register Description Datasheet • PUBLIC DS001047 • v4-00 • 2023-Mar-24 71 │ 61 The status bit NDATA, is re set to “0” after reading the status register or at least one measurement result register. Figure 56: Update Time of the Status Register Bits for an Accurate Measurement and Read Behavior If the buffer registers contain new value s (NDATA = “1”) and new measurement finishes before an I²C reading process occurs, the new measurement results are stored in the buffer registers. The older measurement results are overwritten. The status bit LDATA, shown in Figure 57 indicates this. The LDATA bit is only reset to “0” by reading the status register, as it allows checking for the loss of information after multiple measurement cycles. IDLE MEASUREMENT 2 RESULTS 1 MEASUREMENT 1 CONFIGURATION IDLE TCONV data fetch OSR = 83h start (OSR:SS ← ‚1') MRES1 … MRES3 READY STATE I²C activity RESULTS 2 TCONV start (OSR:SS ← ‚1') LDATA = ‚0' NDATA = ‚0' data fetch LDATA = ‚0' NDATA = ‚1' LDATA = ‚0' NDATA = ‚0' LDATA = ‚0' NDATA = ‚1' LDATA = ‚0' NDATA = ‚0' |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|