26 / 72 page ![]() Document Feedback AS7331 Functional Description Datasheet • PUBLIC DS001047 • v4-00 • 2023-Mar-24 71 │ 25 2. Coming from power down state activated by OSR:PD = “1”, the AS7331 is not actively switched on until OSR:SS is set to “1” (together while or with OSR:DOS = 011b). This means the bit OSR:SS is a direct start condition for the CMD and CONT modes, whereas for both SYN modes, the falling edge at pin SYN is necessary for the startup. The programmed measurement mode follows after startup, marked by the falling edge of the signal path at the READY pin. If the configuration contains CREG3:SB = “1” (as the example in Figure 19 shows), additionally after startup time (TSTARTPD), the wake-up time (TSTARTSB) of 4 µs follows, before the measurement starts. Figure 19: Principle Start of the Measurement from OSR:PD = “1” and CREG3:SB = “1” Figure 19 shows the principle start of the measurement from OSR:PD = “1” and CREG3:SB = “1”: a) CREG3 programming: bit CREG3:SB = “1”, b) OSR programming: C3h, start of the measurement with prior run of TSTARTPD and TSTARTSB. The programmed energy-saving option (before or when the measurement is started or during the measurement) is switched on after the regular end of the measurement and storing of the results within the buffer registers. In case of an abortion of the measurement with OSR:SS = “0” or switching to the configuration state the energy saving option is switched on without saving any results. 7.3.2 Standby Standby is another option for reducing the power consumption, but compared to power down, fewer internal analog components are switched off to be able to become active again in a very short time. The digital part of the AS7331 stays idle, but full communication via the I²C interface is granted in configuration and measurement states. The CREG3:SB bit can only be changed in the configuration mode. The wake-up process is possible in combination with the start condition of the configured measurement mode. Standby is automatically deactivated by starting the CMD or CONT measurement mod e by setting the bit OSR:SS to “1”. In addition, for the measurement modes SYNS and SYND, an initiated start is necessary by the falling edge of the signal at pin SYN. While starting TSTARTSB MEASUREMENT S CONFIGURATION POWDOWN STATE I²C activity OSR C3h b) CREG3:SB ← ‚1' a) TSTARTPD STANDBY |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |