| 数据搜索系统,热门电子元器件搜索 |
|
STPM01 数据表(PDF) 29 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STPM01 数据表(HTML) 29 Page - STMicroelectronics |
|
29 / 56 page ![]() STPM01 Theory of operation 29/56 8.17 Status bits The STPM01 includes 8 status bits that provide several information on the current meter status. The status bits are the following: When STPM01 is used in peripheral mode all these signal can be read through the SPI interface. See paragraph 16 for details on the Status bit location in the STPM01 data records. In standalone mode the BIL signal is available in SCLNLC pin and the BIT signal in the SDATD pin. All the other signals can be read only through SPI interface. 8.18 Programming the STPM01 Data records The STPM01 has 8 internal data records registers. Every data record consists of 4-bit parity code and 28-bit data value where the parity code is computed from the data value, which makes total of 32 bits or 4 bytes. The figure below shows the data records structure with the name of the contained information. Table 15. Status bit description Bit # Name Description Condition 0 BIL No load condition BIL=0: No load condition not detected BIL=1: No load detected 1BCF ∑∆ signals status BCF=0: ∑∆ signals alive BCF=1: one or both ∑∆ signals are stacked 2 BFR Line frequency range BFR=0: Line frequency inside the 45Hz-65Hz range BFR=1: Line frequency out of range 3 BIT Tamper condition BIT=0: Tamper not detected; BIT=1: Tamper detected; 4 MUX Current channel selection MUX=0: Primary current channels selected by the tamper module; MUX=1: Secondary current channels selected by the tamper module; 5 LIN Trend of the line voltage LIN=0: line voltage is going from the minimum to the maximum value. ( ∆v/∆t >0); LIN=1: line voltage is going from the maximum to the minimum value. ( ∆v/∆t < 0); 6 PIN Output pins check PIN=0: the output pins are consistent with the data PIN=1: the output pins are different with the data, this means some output pin is forced to 1 or 0. 7 HLT Data Validity HLT=0: the data records reading are valid. HLT=1: the data records are not valid. A reset occurred and a restart is in progress. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |