| 数据搜索系统,热门电子元器件搜索 |
|
STPM01 数据表(PDF) 47 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STPM01 数据表(HTML) 47 Page - STMicroelectronics |
|
47 / 56 page ![]() STPM01 STPM01 Calibration 47/56 9 STPM01 Calibration Energy meters based on STPM01 device are calibrated in a fast and easy way. The calibration is essentially based on the single calibration of the voltage and current channel considering their RMS values rather than on the frequency of output pulse signal. When the two channel are calibrated all the other measurement are calibrated too. This allows the calibration to be performed in only one point shortening the production time of the meter. This procedure is possible due to the below key points: – Device is compound of two independent meter channels for line voltage and current respectively. Each channel includes its own digital calibrator, to adjust the RMS in the range of ±12.5% in 256 steps, and digital filter, to remove any signal DC component. All final results are not subject to calibration procedure because they are achieved from such corrected signals by mathematical modules implemented by hardwired DSP. – Device computes different kind of energies: active, reactive and apparent. The active energy is produced without 2nd harmonic of line frequency. It also computes rms values of measured voltage and current. – Device produces an energy output pulse signal but information can also be read through Serial Port Interface, SPI, and communication channel. – Device has an embedded memory, 56 bits, used for configuration and calibration purposes. The value of these bits can be read or they can be changed temporarily or permanently through SPI communication channel. Let’s consider the basic information needed to start the calibration procedure: The following typical STPM01 parameters and constants are also known: Table 18. Line RMS voltage Vn (230V) Line RMS current In (5A) Power sensitivity P (LED: P=128000 pulses/kWh, Stepper Motor: PM=P/64= 2000 pulses/kWh) Shunt Sensor KS 0,42 mv/A Table 19. Parameter Value Tolerance Internal reference voltage VBG 1.23 V ± 2% Internal Calculation Frequency fM 223 Hz ± 50 ppm Amplification of voltage ADC AV 4± 1% Amplification of current ADC AI 8, 16, 24, 32 ± 2% Gain of differentiator GDIF 0,6135 Gain of integrator GINT 0,815 Gain of decimation filter GDF 1.004 RMS Voltage register length BV 211 RMS Current register length BI 216 Constant DUD 217 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |