| 数据搜索系统,热门电子元器件搜索 |
|
TNETE2101PZ 数据表(PDF) 12 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TNETE2101PZ 数据表(HTML) 12 Page - Texas Instruments |
|
12 / 39 page ![]() TNETE2101 10BASE-T/100BASE-TX/100BASE-FX LOW-POWER PHYSICAL-LAYER INTERFACE SPWS032D – JANUARY 1997 – REVISED MARCH 1999 12 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 100BASE-FX differential PECL interface The PHY provides three pairs of differential PECL terminals for connection to external fiber-optic transceivers. The data streams are 125-Mbit/s NRZI encoded, with the receive data stream routed to the digital PLL for data recovery. To maintain a reliable lock on the digital PLL, the receive data stream must be jitter free. The FSDP/FSDN serial data-detect pair must be differentially positive to enable data recovery. While this pair is differentially negative, MRCLK is inactive, and no attempt is made to process any receive data appearing on FRCVP/FRCVN. Differential PECL signals should be terminated with a standard emitter-coupled logic (ECL) load of 50 Ω to a voltage source of VDD – 2 V (that is, 1.3 V) or to an equivalent circuit. reset and power up timing At initial power up, the PHY performs an internal reset. No external reset circuitry is required; however, operation of the TNETE2101 is not specified for 50 ms after power up (VDD stable). During operation, a full reset of the device can be performed by taking MRST low for not less than 50 ms. Correct operation of the device is not certain until 50 ms after MRST is deasserted high. 10BASE-T/100BASE-TX PHY operation PHY link establishment The PHY implements the full autonegotiation standard, including next-page capability. CAUTONEG, CSPEED, and CDUPLEX are used to directly configure the link speed or to set and report autonegotiated speeds. When CAUTONEG is deasserted low, CSPEED and CDUPLEX determine the link configuration. CSPEED and CDUPLEX have weak pullups, giving a default configuration of full-duplex 100BASE-TX when not connected. The rising edge of CAUTONEG latches the values of CSPEED and CDUPLEX into the autonegotiation advertisement (AN_adv) register as shown in Table 1. This advertises to the link partner during negotiation of the capabilities of PHY and the highest common link is determined. CSPEED and CDUPLEX then are driven with the negotiated speed and duplex. Table 1. External-Link Configuration Speeds CSPEED CDUPLEX AN_adv ADVERTISED TECHNOLOGIES 0 0 0x0021 Half-duplex 10BASE-T 0 1 0x0061 Half-/full-duplex 10BASE-T 1 0 0x00A1 Half-duplex 10BASE-T Half-duplex 100BASE-TX 1 1 0x00E1 Half-/full-duplex 10BASE-T Half-/full-duplex 100BASE-TX For external controlling and reading of CAUTONEG, CSPEED, and CDUPLEX, timing to be considered is shown in Figure 3. CSPEED and CDUPLEX must not be driven externally for 1200 ms (maximum) after CAUTONEG is asserted high. The PHY begins negotiation when CAUTONEG is asserted. In the final 750 ms (minimum) of autonegotiation, the PHY drives CSPEED and CDUPLEX to indicate the link configuration. The values of these two terminals can be latched on the rising edge of SLINK. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |