| 数据搜索系统,热门电子元器件搜索 |
|
TNETE2101PZ 数据表(PDF) 19 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TNETE2101PZ 数据表(HTML) 19 Page - Texas Instruments |
|
19 / 39 page ![]() TNETE2101 10BASE-T/100BASE-TX/100BASE-FX LOW-POWER PHYSICAL-LAYER INTERFACE SPWS032D – JANUARY 1997 – REVISED MARCH 1999 19 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 Table 6. PHY Generic Control Register Bit Functions BIT FUNCTION NAME NO. FUNCTION RESET 15 PHY reset. Writing a 1 to RESET causes the PHY to be reset and all registers (except GEN_ctl) to be reset to their default values. RESET is self-clearing–it returns a value of 1 when read, until the internal reset is complete (which takes no longer than 500 ms). Writing a 0 to RESET (default) has no effect. This operation can interrupt data communications. LOOPBK 14 Loopback. LOOPBK enables or disables internal loopback within the PHY device. When LOOPBK is set to 1, data is wrapped internally within the PHY and does not appear on the network. When LOOPBK is cleared to 0 (default), data is transmitted to and received from the network. While the PHY is in loopback, all network lines are placed in a noncontentious state. If CLOOPBK is asserted low, loopback is enabled and this bit cannot be set to 0 but is read as 1. SPEED 13 Speed select. Link speed is determined by way of either autonegotiation or manual setting. There are three methods by which the PHY speed can be determined: – Autonegotiation enabled. Speed determined by negotiation. – Autonegotiation disabled by CAUTONEG being low . Speed determined by CSPEED setting. – Autonegotiation disabled by register bit AUTOENB set to a 0. Speed determined by register bit SPEED setting. When SPEED is set to a 1 (default) the PHY speed is 100 Mbit/s and when set to a 0 the PHY speed is 10 Mbit/s. The value read from the SPEED bit always reflects the current PHY speed, regardless of which method is used to select the speed (as described previously). AUTOENB 12 Autonegotiate enable. AUTOENB enables or disables the autonegotiation process if CAUTONEG is high. When AUTOENB is 0, the link is configured by way of the DUPLEX and SPEED bits, and the PHY implements the appropriate link-integrity test. When AUTOENB is set to 1 (default), autonegotiation is enabled and the PHY engages in the autonegotiation process when a LINK FAIL condition is detected or the AUTORSRT bit is set. The link must not be treated as valid until the AUTOCMPLT bit and LINK bit are set to 1. If CAUTONEG terminal is low, autonegotiation is disabled, and AUTOENB cannot be set to 1 but is read as 0. PDOWN 11 Power down. When PDOWN is set to 1, the PHY is placed in a low power-consumption state. The time required for the PHY to power up after PDOWN is cleared can vary considerably. It is good practice to set RESET after this time to make certain that the PHY is in a valid state. If CPWRDOWN is asserted low, the PHY is powered down, and this bit cannot be set to 0 but is read as 1. ISOLATE 10 Isolate. The function of ISOLATE depends on whether the PHY is in repeater mode or node mode (determined by the REPEATER bit in TXPHY_ctl). In node mode, when ISOLATE is set to 1 (default), the PHY electrically isolates its data paths from the MII. In this state, it does not respond to MTXD0–MTXD3, MTXEN, and MTXER inputs, but presents a high impedance on its MTCLK, MRCLK, MRXDV, MRXER, MRXD0–MRXD3, and MCOL outputs. It still responds to management frames on MDIO and MDCLK. In repeater mode, when ISOLATE is set to 1, the PHY presents a high impedance on its MRCLK, MRXDV, MRXER, and MRXD0–MRXD3 outputs only. If CISOLATE is deasserted high, the ISOLATE function is disabled, and this bit cannot be set to 1 but is read as 0. AUTORSRT 9 Restart autonegotiation. If autonegotiation has been enabled by setting AUTOENB to 1, the autonegotiation process can be restarted by setting AUTORSRT to 1. AUTORSRT is self clearing, and the PHY returns a value of 1 in this bit until autonegotiation fast-link pulse (FLP) data-burst transmission has been initiated. When AUTOENB is cleared to 0, AUTORSRT is read as 0. The default value of AUTORSRT is 0. DUPLEX 8 Duplex mode. Duplex mode is determined by way of either autonegotiation or normal setting. There are three ways the PHY speed can be determined: – Autonegotiation enabled. Duplex determined by negotiation. – Autonegotiation disabled by CAUTONEG being low. Duplex determined by CDUPLEX setting. – Autonegotiation disabled by register bit AUTOENB set to a 0. Duplex determined by register bit DUPLEX setting. When DUPLEX is set to 1 (default), the PHY is in full duplex. When DUPLEX is set to 0, the PHY is in half duplex. The value read from the DUPLEX bit always reflects the current PHY duplex, regardless of which is used to select the duplex, (as described previously). COLTEST 7 Collision test mode. When COLTEST is set to 1 and LOOPBK is set to 1, the PHY asserts the collision-detect signal MCOL when transmit enable MTXEN is asserted. The default value of COLTEST is 0. Reserved 6–0 Reserved. Read and write as 0. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |