7 / 28 page ![]() 7/28 M39432 Automatic Stand-by If CMOS levels (VCC±0.2V) are used to drive the bus, and the bus is inactive for more than 150 ns, the memory enters the Automatic Stand-by state. The internal supply current is reduced to the Stand-by Supply Current, ICC3. Deep Power Down The ICC consumption mode can be reduced to a minimum using the Deep Power Down instruction (as shown in Table 4). The device is set in a sleep mode until the next Reset instruction is executed. EEPROM Power Down The M39432 can power-down the EEPROM block using the specific instruction shown in Table 4. Once in this state, the EEPROM block is no longer accessible, until a Return instruction is executed. READ Read operations and instructions can be used: – to read the contents of the memory array (Flash memory block or EEPROM block) – to read the memory array status and identifiers (Flash memory block or EEPROM block). Read Data (from Flash Memory or EEPROM) For a Read operation, the Output Enable (G) and one Chip Enable (EF or EE) must be driven low. Read the Manufacturer Identifier There are two alternative methods for reading the Manufacturer Identifier: using a Read operation or using a Read instruction. Read Operation. The Manufacturer Identifier can be read with a Read operation by applying VID (as specified in Table 11) on A9, and the logic levels specified in Table 5 applied to A0, A1, A6. Read Instruction. The Manufacturer Identifier can also be read using an instruction composed of four operations: three specific Write operations (as specified in Table 4) and a Read operation. This either accesses the Manufacturer Identifier, the Flash Block Identifier or the Flash Sector Protection Status, depending on the levels that are being applied to A0, A1, A6, A16, A17 and A18. Read the Flash Block Identifier Similarly, there are two alternative methods for reading the Flash Block Identifier (E3h): using a Read operation or using a Read instruction. Please see the previous section, entitled “Read the Manufacturer Identifier”, and Table 5 and Table 4 for details. Read the EEPROM Block Identifier The EEPROM Block Identifier (64 bytes, user de- fined) can be read with a single Read operation by holding A6 low and A9 at VID (see Table 5). Read the OTP Row The OTP row is mapped in the EEPROM block. With EE held low, and EF held high, an EEPROM Read instruction is composed, as specified in Table 6. Status Bits Note: 1. X = Not a guaranteed value, can be read either as ‘1’ or ‘0’. EF EE DQ7 DQ6 DQ5 DQ4 DQ3 DQ2 DQ1 DQ0 Flash VIL VIH Data Polling Toggle Flag Error Flag X Erase Time- Out XX X EEPROM VIH VIL Data Polling Toggle Flag XX XX XX Figure 4. Data Polling Flowchart READ DQ5 & DQ7 at VALID ADDRESS START READ DQ7 FAIL PASS AI01369B DQ7 = DATA YES NO YES NO DQ5 = 1 DQ7 = DATA YES NO |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |