| 数据搜索系统,热门电子元器件搜索 |
|
M50FW080 数据表(PDF) 29 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M50FW080 数据表(HTML) 29 Page - STMicroelectronics |
|
29 / 56 page ![]() M50FW080 Status Register 29/55 5.3 Erase status (bit 5) The Erase Status bit can be used to identify if the memory has applied the maximum number of erase pulses to the block(s) and still failed to verify that the block(s) has erased correctly. The Erase Status bit should be read once the Program/Erase Controller Status bit is ‘1’ (Program/Erase Controller inactive). When the Erase Status bit is ‘0’ the memory has successfully verified that the block(s) has erased correctly; when the Erase Status bit is ‘1’ the Program/Erase Controller has applied the maximum number of pulses to the block(s) and still failed to verify that the block(s) has erased correctly. Once the Erase Status bit is set to ‘1’ it can only be reset to ‘0’ by a Clear Status Register command or a hardware reset. If it is set to ‘1’ it should be reset before a new Program or Erase command is issued, otherwise the new command will appear to fail. 5.4 Program status (bit 4) The Program Status bit can be used to identify if the memory has applied the maximum number of program pulses to the byte and still failed to verify that the byte has programmed correctly. The Program Status bit should be read once the Program/Erase Controller Status bit is ‘1’ (Program/Erase Controller inactive). When the Program Status bit is ‘0’ the memory has successfully verified that the byte has programmed correctly; when the Program Status bit is ‘1’ the Program/Erase Controller has applied the maximum number of pulses to the byte and still failed to verify that the byte has programmed correctly. Once the Program Status bit is set to ‘1’ it can only be reset to ‘0’ by a Clear Status Register command or a hardware reset. If it is set to ‘1’ it should be reset before a new Program or Erase command is issued, otherwise the new command will appear to fail. 5.5 VPP status (bit 3) The VPP Status bit can be used to identify an invalid voltage on the VPP pin during Program and Erase operations. The VPP pin is only sampled at the beginning of a Program or Erase operation. Indeterminate results can occur if VPP becomes invalid during a Program or Erase operation. When the VPP Status bit is ‘0’ the voltage on the VPP pin was sampled at a valid voltage; when the VPP Status bit is ‘1’ the VPP pin has a voltage that is below the VPP Lockout Voltage, VPPLK, the memory is protected; Program and Erase operation cannot be performed. Once the VPP Status bit set to ‘1’ it can only be reset to ‘0’ by a Clear Status Register command or a hardware reset. If it is set to ‘1’ it should be reset before a new Program or Erase command is issued, otherwise the new command will appear to fail. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |