| 数据搜索系统,热门电子元器件搜索 |
|
M50FW080 数据表(PDF) 32 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M50FW080 数据表(HTML) 32 Page - STMicroelectronics |
|
32 / 56 page ![]() Firmware Hub (FWH) interface Configuration Registers M50FW080 32/55 6 Firmware Hub (FWH) interface Configuration Registers When the Firmware Hub Interface is selected several additional registers can be accessed. These registers control the protection status of the Blocks, read the General Purpose Input pins and identify the memory using the Electronic Signature codes. See Table 11 for the memory map of the Configuration Registers. 6.1 Lock Registers The Lock Registers control the protection status of the Blocks. Each Block has its own Lock Register. Three bits within each Lock Register control the protection of each block, the Write Lock Bit, the Read Lock Bit and the Lock Down Bit. The Lock Registers can be read and written, though care should be taken when writing as, once the Lock Down Bit is set, ‘1’, further modifications to the Lock Register cannot be made until cleared, to ‘0’, by a reset or power-up. See Table 12 for details on the bit definitions of the Lock Registers. 6.1.1 Write Lock The Write Lock Bit determines whether the contents of the Block can be modified (using the Program or Block Erase Command). When the Write Lock Bit is set, ‘1’, the block is write protected; any operations that attempt to change the data in the block will fail and the Status Register will report the error. When the Write Lock Bit is reset, ‘0’, the block is not write protected through the Lock Register and may be modified unless write protected through some other means. When VPP is less than VPPLK all blocks are protected and cannot be modified, regardless of the state of the Write Lock Bit. If Top Block Lock, TBL, is Low, VIL, then the Top Block (Block 15) is write protected and cannot be modified. Similarly, if Write Protect, WP, is Low, VIL, then the Main Blocks (Blocks 0 to 14) are write protected and cannot be modified. After power-up or reset the Write Lock Bit is always set to ‘1’ (write protected). 6.1.2 Read Lock The Read Lock bit determines whether the contents of the Block can be read (from Read mode). When the Read Lock Bit is set, ‘1’, the block is read protected; any operation that attempts to read the contents of the block will read 00h instead. When the Read Lock Bit is reset, ‘0’, read operations in the Block return the data programmed into the block as expected. After power-up or reset the Read Lock Bit is always reset to ‘0’ (not read protected). |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |