29 / 136 page ![]() Preliminary Technical Data ADE7566/ADE7569 Rev. PrA | Page 29 of 136 USING THE POWER SUPPLY FEATURES In an energy meter application, the 3.3 V power supply (VDD), is typically generated from the ac line voltage and regulated to 3.3 V by a voltage regulator IC. The pre-regulated dc voltage, typically 5 V to 12 V, can be connected to VDCIN through a resistor divider. A 3.6 V battery can be connected to VBAT. Figure 24 shows how the ADE7566/ADE7569 power supply inputs would be set up in this application. Figure 25 shows the sequence of events that would occur if the main power supply generated by the PSU started to fail in the power meter application shown in Figure 24. The SAG detection can provide the earliest warning of a potential problem on VDD. When a SAG event occurs, the user code can be configured to backup data and prepare for battery switchover if desired. The relative spacing of these interrupts depends on the design of the power supply. Figure 26 shows the sequence of events that would occur if the main power supply started to fail in the power meter application shown in Figure 24, with battery switchover on low VDCIN or low VDD enabled. Finally, the transition between VDD and VBAT and the different Power Supply Modes (see the Operating Modes section) are represented in Figure 28. VOLTAGE SUPERVISORY POWER SUPPLY MANAGEMENT IPSMF SFR (ADDR. 0xF8) VSW VBAT VSWOUT VDD 58 61 60 VOLTAGE SUPERVISORY 64 VDCIN 3.3V REGULATOR 5V TO 12V DC PSU 50 SAG DETECTION 49 45 BCTRL VP VN (240V, 220V, 110V TYPICAL) AC INPUT Figure 24. Power Supply Management for Energy Meter Application t1 t2 VDD VDCIN VP – VN 2.75V 1.2V SAG LEVEL TRIP POINT SAGCYC = 1 SAG EVENT (FSAG = 1) VDCIN EVENT (FVDCIN = 1) IF SWITCHOVER ON LOW VDD IS ENABLED, AUTOMATIC BATTERY SWITCHOVER VSW CONNECTED TO VBAT BSO EVENT (FBSO = 1) Figure 25. Power Supply Management Interrupts and Battery Switchover with Only VDD Enabled for Battery Switchover |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |