| 数据搜索系统,热门电子元器件搜索 |
|
STULPI01A 数据表(PDF) 19 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STULPI01A 数据表(HTML) 19 Page - STMicroelectronics |
|
19 / 44 page ![]() STULPI01A - STULPI01B Block description 19/44 6.6 External charge pump It is possible to use an external charge pump or power switch controlled by the PSWn pin (active low open drain). This functionality is controlled by DrvVbus and DrvVbusExternal ULPI OTG Control register bits. 6.7 VBUS comparators and VBUS over current (OC) detector These comparators monitor the VBUS voltage. VBUS valid status signalizes that the voltage is above the VBUS_VLD level (4.4 V). Session valid status signalizes that the VBUS voltage is above the VSESS_VLD level (0.8 to 2.0 V). Session end detector signalizes VBUS voltage is below VSESS_END level. STULPI01 also implements embedded VBUS over current detector which compares VBUS voltage to external analog 5 V reference signal applied to VB_REF_FAULT pin. 6.8 VB_REF_FAULT pin VBUS over-current conditions can be monitored by either internal or an external OC detector. The internal OC detector is enabled when over-current_PD bit in the Power Control register (Vendor-specific area) is set to 0b and Use External VBUS Indicator is set to 1b. In this mode, the VB_REF_FAULT pin functions as the input of the analog reference for internal over-current detector. If the external charge pump is already equipped with an over-current detector, its output can be also monitored through VB_REF_FAULT pin, but over-current_PD bit must be set to 1b. In this mode VB_REF_FAULT will function as standard digital input pin with 5 V tolerance. Functionality of VB_REF_FAULT pin can be seen in more detail (on Figure 6). Note: After reset, over-current_PD bit is 1b, internal over-current detector is disabled. Figure 6. VB_REF_FAULT pin functionality + - REF VBREF_FAULT Internal VBUS Valid VBUSVLD [UseExternalVbusIndicator, IndicatorPassthru] RX CMD VBUS Valid 2 0 1 [0,X] [1,0] [1,1] BUS VB REF V BUS SCHMIT (5 V TOLERANT) VBUS FAULT + - VBOC EN /EN + - Valid IndicatorComplement OverCurrent_PD or neg (UseExternalVbusIndicator) 0 1 [0,X] [1,1] V V VBUS + - VBOC RIN_VBREF + - REF VBREF_FAULT Internal VBUS Valid VBUSVLD [UseExternalVbusIndicator, IndicatorPassthru] RX CMD VBUS Valid 2 0 1 [0,X] [1,0] [1,1] BUS VB REF V BUS SCHMIT (5 V TOLERANT) VBUS FAULT + - VBOC EN /EN + - Valid IndicatorComplement OverCurrent_PD or neg (UseExternalVbusIndicator) 0 1 [0,X] [1,1] V V VBUS + - VBOC RIN_VBREF |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |