28 / 32 page ![]() LTC4261/LTC4261-2 28 42612fb Table 3. STATUS Register A (00h)—Read Only BIT NAME OPERATION A7 FET On Indicates State of FET; 1 = FET On, 0 = FET Off A6 PGIO Input Indicates State of the PGIO Pin when Configured to General Purpose Input: 1 = PGIO High, 0 = PGIO Low A5 FET Short Indicates Potential FET Short if Current Sense Voltage Exceeds 2mV While FET is Off; 1 = FET is Shorted, 0 = FET is Not Shorted A4 EN Indicates State of the EN Pin; 1 = EN Pin High, 0 = EN Pin Low A3 Power Bad Indicates Power is Bad when PGI is High at the End of the PGI Check Timer; 1 = PGI High, 0 = PGI Low A2 Overcurrent Indicates Overcurrent Condition; 1 = Overcurrent, 0 = Not Overcurrent A1 Undervoltage Indicates Input Undervoltage when Both UVH and UVL are Low; 1 = UVH and UVL Low, 0 = UVH or UVL High A0 Overvoltage Indicates Input Overvoltage when OV is High; 1 = OV High, 0 = OV Low Table 4. FAULT Register B (01h)—Read/Write BIT NAME OPERATION B7 External Fault Occurred Latched to 1 if FLTIN Goes Low; 1 = FLTIN Low State Detected, 0 = FLTIN has Not Been Low B6 PGIO Input High Occurred Latched to 1 if the PGIO Pin Goes High when Configured to General Purpose Input; 1 = PGIO High Detected, 0 = PGIO has Been Low B5 FET Short Fault Occurred Indicates Potential FET Short was Detected When Measured Current Sense Voltage Exceeded 2mV While FET was Off; 1 = FET Short Fault Occurred, 0 = No FET Short Fault B4 EN Changed State Indicates That a Board was Inserted or Extracted when EN Changed State; 1 = EN Changed State, 0 = EN Unchanged B3 Power Bad Fault Occurred Indicates Power was Bad when PGI was High at the End of the PGI Check Timer; 1 = Power Bad Fault Occurred, 0 = No Power Bad Fault B2 Overcurrent Fault Occurred Indicates Overcurrent Fault Occurred; 1 = Overcurrent Fault Occurred, 0 = No Overcurrent Fault B1 Undervoltage Fault Occurred Indicates Input Undervoltage Fault Occurred when Both UVH and UVL went Low; 1 = Undervoltage Fault Occurred, 0 = No Undervoltage Fault B0 Overvoltage Fault Occurred Indicates Input Overvoltage Fault Occurred when OV was High; 1 = Overvoltage Fault Occurred, 0 = No Overvoltage Fault Table 5. ALERT Register C (02h)—Read/Write BIT NAME OPERATION C7 External Fault Alert Enables Alert for External Fault When FLTIN was Low; 1 = Enable Alert, 0 = Disable Alert (Default) C6 PGIO Output Output Data Bit to PGIO Pin when Configured as Output. Defaults to 0 C5 FET Short Alert Enables Alert for FET Short Fault; 1 = Enable Alert, 0 = Disable Alert (Default) C4 EN State Change Alert Enables Alert when EN Changed State; 1 = Enable Alert, 0 Disable Alert (Default) C3 Power Bad Alert Enables Alert for Power Bad Fault; 1 = Enable Alert, 0 Disable Alert (Default) C2 Overcurrent Alert Enables Alert for Overcurrent Fault; 1 = Enable Alert, 0 Disable Alert (Default) C1 Undervoltage Alert Enables Alert for Undervoltage Fault; 1 = Enable Alert, 0 Disable Alert (Default) C0 Overvoltage Alert Enables Alert for Overvoltage Fault; 1 = Enable Alert, 0 Disable Alert (Default) APPLICATIONS INFORMATION |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |