24 / 65 page ![]() PCF2113_FAM_4 © NXP B.V. 2008. All rights reserved. Product data sheet Rev. 04 — 4 March 2008 24 of 65 NXP Semiconductors PCF2113x LCD controllers/drivers 9. Instructions Only two PCF2113x registers, the Instruction Register (IR) and the Data Register (DR), can be directly controlled by the microcontroller. Before internal operation, control information is stored temporarily in these registers to allow interfacing to various types of microcontrollers which operate at different speeds or to allow interfacing to peripheral control ICs. The instruction set for I2C-bus commands is given in Table 9. Section 11.2.1 discusses how these control and command bytes are embedded in the I2C-bus protocol. [1] R/W is set together with the slave address. [2] For explanation, see Table 11. The PCF2113x operation is controlled by the instructions shown in Table 10 together with their execution time. Details are explained in subsequent sections. Table 8. State after reset Step Function Control bit state Conditions 1 clear display 2 entry mode set I/D = 1 +1 (increment) S = 0 no shift 3 display control D = 0 display off C = 0 cursor off B = 0 cursor character blink off 4 function set DL = 1 8-bit interface M = 0 1-line display H = 0 normal instruction set SL = 0 MUX 1:18 mode 5 default address pointer to DDRAM the Busy Flag (BF) indicates the busy state (BF = 1) until initialization ends the busy state lasts 2 ms; the chip may also be initialized by software; see Table 26 (8-bit interface) and Table 27 (4-bit interface). 6 icon control IM = 0; IB = 0; DM = 0 icons, icon blink and Direct mode disabled 7 display or screen configuration L = 0; P = 0; Q = 0 default configurations 8VLCD temperature coefficient TC1 = 0; TC2 = 0 default temperature coefficient 9 set VLCD VA = 0; VB = 0 VLCD generator off 10 I2C-bus interface reset 11 set HVgen stages S1 = 1; S0 = 0 VLCD generator voltage multiplier set at factor 4 Table 9. Instruction set for I2C-bus commands I2C-bus commands Control byte Command byte I2C-bus commands [1] Co[2] RS 000000 DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0 [1] |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |