| 数据搜索系统,热门电子元器件搜索 |
|
68HC05CL48 数据表(PDF) 65 Page - Motorola, Inc |
|
|
|||||||||||||||||||||||||||||
68HC05CL48 数据表(HTML) 65 Page - Motorola, Inc |
|
65 / 145 page ![]() June 11, 1997 GENERAL RELEASE SPECIFICATION MC68HC05CL48 TIMER MOTOROLA REV 2.0 8-13 IC1F - Input Capture Flag 1 = Flag set when a selected polarity edge has been sensed by the input capture edge detector. 0 = Flag cleared by reading the timer status register (with IC1F set) followed by accessing the low byte ($14) of the input capture register. IC2F - Input Capture Flag 1 = Flag set when a selected polarity edge has been sensed by the input capture edge detector. 0 = Flag cleared by reading the timer status register (with IC2F set) followed by accessing the low byte ($10) of the input capture register. OC1F - Output Compare 1 Flag 1 = Flag set when the output compare register 1 contents matches the contents of the free running counter. 0 = Flag cleared by reading the timer status register (with OC1F set) and then accessing the low byte ($16) of the output compare 1 register. OC2F - Output Compare 2 Flag 1 = Flag set when the output compare register 2 contents matches the contents of the free running counter. 0 = Flag cleared by reading the timer status register (with OC2F set) and then accessing the low byte ($18) of the output compare 1 register. TOF - Timer OVerflow Flag 1 = Flag set by transition of the free running counter from $FFFF to $0000. 0 = Flag cleared by reading the timer status register (with TOF set) followed by an access of the free running counter least significant byte ($1A). Accessing the timer status register satisfies the first condition required to clear status bits. The remaining step is to access the register corresponding to the status bit. A problem can occur when using the timer overflow function and reading the free- running counter at random times to measure an elapsed time. Without incorporating the proper precautions into software, the timer overflow flag could unintentionally be cleared if: 1. The timer status register is read or written when TOF is set, and 2. The LSB of the free-running counter is read but not for the purpose of servicing the flag. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |