| 数据搜索系统,热门电子元器件搜索 |
|
TNETX3110 数据表(PDF) 27 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TNETX3110 数据表(HTML) 27 Page - Texas Instruments |
|
27 / 65 page ![]() TNETX3110 ThunderSWITCH ™ 8/3 ETHERNET™ SWITCH WITH 8 10-MBIT/S PORTS AND 3 10-/100-MBIT/S PORTS SPWS047A – MARCH 1998 – REVISED APRIL 1999 27 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 EEPROM interface (continued) Multiple bus masters are not supported on the EEPROM interface because the ECLK pin always is driven by the device with a strong 0/strong 1 (i.e., not a strong 1/resistively pulled-up 1). An Ethernet CRC check is used to ensure the EEPROM data is valid. The 4-byte CRC should be placed within the EEPROM in four data bytes immediately following the last byte to be loaded (equivalent to locations 0x00FC–0x00FF, just above Syscontrol). As each byte is loaded from the EEPROM, the bits within that byte are entered into the CRC checker bit-wise, most significant bit first. A valid CRC always must be provided by the EEPROM. The EEPROM data for the most significant bit of Syscontrol is withheld until the CRC computed by the device has been checked against the one read from the EEPROM. If the CRC is invalid: D The reset bit is set to 1 in Syscontrol, load and initd are both 0, and the TNETX3110 does not begin operation. D The fault LED is illuminated and remains in that state until the TNETX3110 is hardware reset or until load in Syscontrol is set to 1. interaction of EEPROM load with the SIO register The EDIO pin is shared with the SIO register edata bit. The edata and etxen bits must not both be set to 1 when the load bit is set or the EDIO pin is held at resistive 1 and the EEPROM load fails. The value of the eclk bit in SIO is don’t care when load is set, but to ensure the EEPROM does not see a glitch on its clock signal, the load bit should not be set until the minimum clock high or low time required by the EEPROM on its clock signal has expired since the eclk bit was last changed. The SIO register is not loaded during the EEPROM download. summary of EEPROM load outcomes Table 6 summarizes the various states of register bits and the fault LED for each possible outcome, following an EEPROM load attempt. Table 6. Summary of EEPROM Load Outcomes OUTCOME STOP LOAD INITD† FAULT LED ECLK Successful load 0 0 1 0‡ Not locked No EEPROM present 0 0 0 0‡ Locked CRC error detected 1 0 0 1 Not locked † Assuming the start bit was set to 1 by the EEPROM load ‡ Assuming the fault bit in LEDControl = 0 and no memory system parity error is detected compatibility with future device revisions All EEPROM locations that correspond to reserved addresses in the memory map, register bits that are read only, and register bits that are marked as reserved should be set to 0 to ensure compatibility with future versions of the device. Failure to do so may result in the unintentional activation of features in future devices. All such bits are included in the CRC calculation. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |