41 / 172 page ![]() STA382BW I2C bus specification Doc ID 022783 Rev 1 41/172 the 9th bit time. The byte following the device identification byte is the internal space address. 5.3 Write operation Following the START condition, the master sends a device select code with the RW bit set to 0. The STA382BW acknowledges this and then waits for the byte of the internal address. After receiving the internal byte address the STA382BW again responds with an acknowledgement. 5.3.1 Byte write In the byte write mode the master sends one data byte which is acknowledged by the STA382BW. The master then terminates the transfer by generating a STOP condition. 5.3.2 Multi-byte write The multi-byte write mode can start from any internal address. The master generating a STOP condition terminates the transfer. 5.4 Read operation 5.4.1 Current address byte read Following the START condition, the master sends a device select code with the RW bit set to 1. The STA382BW acknowledges this and then responds by sending one byte of data. The master then terminates the transfer by generating a STOP condition. 5.4.2 Current address multi-byte read The multi-byte read modes can start from any internal address. Sequential data bytes are read from sequential addresses within the STA382BW. The master acknowledges each data byte read and then generates a STOP condition, terminating the transfer. 5.4.3 Random address byte read Following the START condition, the master sends a device select code with the RW bit set to 0. The STA382BW acknowledges this and then the master writes the internal address byte. After receiving the internal byte address, the STA382BW again responds with an acknowledgement. The master then initiates another START condition and sends the device select code with the RW bit set to 1. The STA382BW acknowledges this and then responds by sending one byte of data. The master then terminates the transfer by generating a STOP condition. 5.4.4 Random address multi-byte read The multi-byte read mode can start from any internal address. Sequential data bytes are read from sequential addresses within the STA382BW. The master acknowledges each data byte read and then generates a STOP condition, terminating the transfer. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |