| 数据搜索系统,热门电子元器件搜索 |
|
M24LR64E-R 数据表(PDF) 30 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M24LR64E-R 数据表(HTML) 30 Page - STMicroelectronics |
|
30 / 140 page ![]() System memory area M24LR64E-R 30/140 Doc ID 022712 Rev 3 4.3.3 FIELD_ON indicator bit The FIELD_ON indicator bit located as bit 1 of the Control register is a read-only bit used to indicate when the RF power level delivered to the M24LR64E-R is sufficient to execute RF commands. ● When FIELD_ON = 0, the M24LR64E-R is not able to execute any RF commands. ● When FIELD_ON =1, the M24LR64E-R is able to execute any RF commands. Note: During read access to the Control register in RF mode, the FIELD_ON bit is always read at 1. 4.3.4 Configuration byte access in I²C and RF modes In I²C mode, read and write accesses to the non-volatile Configuration byte are always allowed. To access the Configuration byte, the device select code used for any I²C command must have the E2 Chip enable address at 1. The dedicated commands to access the Configuration byte in RF mode are: ● Read configuration byte command (ReadCfg): – The ReadCfg command is used to read the eight bits of the Configuration byte. ● Write energy harvesting configuration command (WriteEHCfg): – The WriteEHCfg command is used to write the EH_mode, EH_cfg1 and EH_cfg0 bits into the Configuration byte. ● Write RF WIP/BUSY pin configuration command (WriteDOCfg): – The WriteDOCfg command is used to write the RF WIP/BUSY bit into the Configuration byte. After any write access to the Configuration byte, the new configuration is automatically applied. 4.3.5 Control register access in I²C or RF mode In I²C mode, read and write accesses to the volatile Control register are always allowed. To access the Control register, the device select code used for any I²C command must have the E2 Chip enable address at 1. The dedicated commands to access the Control register in RF mode are: ● Check energy harvesting enable bit command (CheckEHEn): – The CheckEHEn command is used to read the eight bits of the Control register. When it is run, the FIELD_ON bit is always read at 1. ● Set/reset energy harvesting enable bit command (SetRstEHEn): – The SetRstEHEn command is used to set or reset the value of the EH_enable bit into the Control register. 4.4 ISO 15693 system parameters The M24LR64E-R provides the system area required by the ISO 15693 RF protocol, as shown in Table 17. The first 32-bit block starting from I2C address 2304 stores the I2C password. This password is used to activate/deactivate the write protection of the protected sector in I2C mode. At |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |