6 / 20 page ![]() DA6502.008 29 November 2012 6 (20) OPERATING MODES MAS6502 has two operating modes, pressure and temperature measurement mode. In the pressure mode the pressure dependent sensor bridge voltage is connected to the ADC input. In the temperature measurement mode the resistive sensor is connected into a Wheatstone resistor bridge circuit together with four internal resistors (see Temperature Measurement Configuration in the Application Information chapter) and the temperature dependent bridge output voltage is connected to the ADC input. Switching between pressure and temperature measurement modes is done via the single ADC control register. The measurement configuration includes selection of over sampling ratio, input signal range, offset and sensor resistance. By writing an 8-bit configuration data to the ADC control register a new A/D conversion is started. See further details in the ADC Control Register chapter. MAS6502 includes a 256-bit EEPROM memory for storing trimming and calibration data on chip. The first 8-bits of EEPROM are reserved for internal oscillator trimming but the remaining 248-bits are free for calibration and other data. The stored calibration data should comprise of calibration and temperature compensation coefficients which can be used to calculate accurate calibrated pressure and temperature measurement results from the non-calibrated measurement results. All calculations need to be done in the external micro controller unit (MCU). A calibrated MAS6502 sensor system is operated as illustrated in figure 2. The calibration and compensation coefficients need to be read to the MCU memory only once. From each pair of pressure and temperature measurements results the accurate pressure and temperature values are then calculated by using the external MCU. All communication with MAS6502 is done using the bi-directional I 2C ® bus compatible 2-wire serial bus. Starting an A/D conversion, reading out the conversion result and reading and writing data from and to the EEPROM memory are all accomplished via serial bus communication. In addition to the I 2C ® bus the digital interface includes also end-of-conversion (EOC) and master reset (XCLR) pins. See A/D Conversion in the Serial Data Interface (I 2C ® Bus) Control chapter. Figure 2. Flow chart for a calibrated MAS6502 sensor system START READ EEPROM CALIBRATION DATA MEASURE PRESSURE MEASURE TEMPERATURE CALCULATE CALIBRATED TEMPERATURE CALCULATE TEMPERATURE COMPENSATED PRESSURE |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |