| 数据搜索系统,热门电子元器件搜索 |
|
AD9888/PCB 数据表(PDF) 26 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9888/PCB 数据表(HTML) 26 Page - Analog Devices |
|
26 / 32 page ![]() REV. A AD9888 –26– 2-WIRE SERIAL CONTROL PORT A 2-wire serial interface control interface is provided. Up to two AD9888 devices may be connected to the 2-wire serial interface, with each device having a unique address. The 2-wire serial interface comprises a clock (SCL) and a bidirec- tional data (SDA) pin. The AD9888 acts as a slave for receiving and transmitting data over the serial interface. When the serial interface is not active, the logic levels on SCL and SDA are pulled HIGH by external pull-up resistors. Data received or transmitted on the SDA line must be stable for the duration of the positive-going SCL pulse. Data on SDA must change only when SCL is LOW. If SDA changes state while SCL is HIGH, the serial interface interprets that action as a start or stop sequence. There are six components to serial bus operation: Start signal Slave address byte Base register address byte Data byte to read or write Stop signal When the serial interface is inactive (SCL and SDA are HIGH), communications are initiated by sending a start signal. The start signal is a HIGH-to-LOW transition on SDA while SCL is HIGH. This signal alerts all slaved devices that a data transfer sequence is coming. The first eight bits of data transferred after a start signal comprise a 7-bit slave address (the first seven bits) and a single R/ W bit (the eighth bit). The R/ W bit indicates the direction of data transfer, read from (1) or write to (0) the slave device. If the transmitted slave address matches the address of the device (set by the state of the A0 input pin in Table XLI), the AD9888 acknowledges by bringing SDA LOW on the ninth SCL pulse. If the addresses do not match, the AD9888 does not acknowledge Table XLI. Serial Port Addresses Bit 7 (MSB) Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 A6 A5 A4 A3 A2 A1 A0 1 0 0110 0 1 0 0110 1 Data Transfer via Serial Interface For each byte of data read or written, the MSB is the first bit of the sequence. If the AD9888 does not acknowledge the master device during a write sequence, the SDA remains HIGH so the master can generate a stop signal. If the master device does not acknowledge the AD9888 during a read sequence, the AD9888 interprets this as “end of data.” The SDA remains HIGH so the master can generate a stop signal. Writing data to specific control registers of the AD9888 requires that the 8-bit address of the control register of interest be writ- ten after the slave address has been established. This control register address is the base address for subsequent write opera- tions. The base address autoincrements by one for each byte of data written after the data byte intended for the base address. If more bytes are transferred than there are available addresses, the address will not increment and remain at its maximum value of 19h. Any base address higher than 19h will not produce an ACKnowledge signal. Data are read from the control registers of the AD9888 in a similar manner. Reading requires two data transfer operations. The base address must be written with the R/ W bit of the slave address byte LOW to set up a sequential read operation. Reading (the R/ W bit of the slave address byte HIGH) begins at the previously established base address. The address of the read register autoincrements after each byte is transferred. To terminate a read/write sequence to the AD9888, a stop sig- nal must be sent. A stop signal comprises a LOW-to-HIGH transition of SDA while SCL is HIGH. A repeated start signal occurs when the master device driving the serial interface generates a start signal without first generat- ing a stop signal to terminate the current communication. This is used to change the mode of communication (read, write) between the slave and master without releasing the serial inter- face lines. Serial Interface Read/Write Examples Write to One Control Register Start Signal Slave Address Byte (R/ W Bit = LOW) Base Address Byte Data Byte to Base Address Stop Signal Write to Four Consecutive Control Registers Start Signal Slave Address Byte (R/ W Bit = LOW) Base Address Byte Data Byte to Base Address Data Byte to (Base Address + 1) Data Byte to (Base Address + 2) Data Byte to (Base Address + 3) Stop Signal Read from One Control Register Start Signal Slave Address Byte (R/ W Bit = LOW) Base Address Byte Start Signal Slave Address Byte (R/ W Bit = HIGH) Data Byte from Base Address Stop Signal Read from Four Consecutive Control Registers Start Signal Slave Address Byte (R/ W bit = LOW) Base Address Byte Start Signal Slave Address Byte (R/ W Bit = HIGH) Data Byte from Base Address Data Byte from (Base Address + 1) Data Byte from (Base Address + 2) Data Byte from (Base Address + 3) Stop Signal |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |