| 数据搜索系统,热门电子元器件搜索 |
|
K3HB-R 数据表(PDF) 22 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
K3HB-R 数据表(HTML) 22 Page - Omron Electronics LLC |
|
22 / 32 page ![]() 22 Digital Indicators K3HB-R/-P/-C Connections The BCD COMMON is shared. The pins indicated in the above diagram as blank (white) boxes have been removed. *Only one of the following can be used for each Digital Indicator: communications, BCD, or DeviceNet. DeviceNet Connector (Included) <DRT> Relay Outputs <C2> Relay Outputs <C1> Transistor Outputs <T1> <T2> NPN PNP HH H PASS L LL COM C1 C2 C3 C4 C5 C6 RS-232C <FLK1A> RS-485 <FLK3A> B1 B2 B3 B4 B5 B6 B1 B2 B3 B4 B5 B6 B1 B2 B3 B4 B5 B6 <L2A> <L1A> + − + − SD RD SG N/C 12 VDC 80 mA B ( +) A ( −) B ( +) A ( −) 12 VDC 80 mA 12 VDC 80 mA 12 VDC 80 mA 0-20/ 4-20 mA N/C 0-5/1-5/ 0-10 V N/C <A> 12 VDC 80 mA + − + − + − <CPA> 12 VDC 80 mA N/C N/C PASS Sensor power supply B1 B2 B3 B4 B5 B6 HH H COM L H L LL COM C1 C2 C3 C4 C5 C6 C1 C2 C3 C4 C5 C6 Sensor power supply Sensor power supply Sensor power supply + communications Sensor power supply Sensor power supply AB C D E 1 2 3 4 5 6 100 to 240 VAC 24 VAC/VDC A1 A2 HH H L LL PASS BCD (NPN Open Collector): <BCD> Applicable Connector (Sold separately) HDR-E50MAG1 (HONDA TSUSHIN KOGYO CO., LTD.) Special Cable (Sold separately) K32-BCD (OMRON) (HDR-E50MAG1 with 0.3-m cable) 5 V HH H L LL PASS A Operating Power Supply *Check the required power supply type. Sensor power supply + PASS output Sensor power supply + linear output B Sensor Power Supply/Output C Relays, Transistors, BCD and DeviceNet 1: V − (Power supply cable: Black) 2: CAN L (Communications cable: Blue) 3: Shield 4: CAN H (Communications cable: White) 5: V+ (Power supply cable: Red) Applicable Connector: HR31-5.08P-5SC (01) (HIROSE ELECTRIC CO., LTD.) * Attach the provided crimp terminals. Contact Outputs Transistor Outputs (NPN Open Collector) • Always use a EN/IEC-compliant power supply with reinforced insulation or double insulation for the DeviceNet power supply. • The product must be used indoors for the above applicable standards to apply. Safety Standards Conformance ■ External Connection Diagrams Terminal Arrangements Note: Refer to “Internal Block Diagram” on page 24 for information on isolation. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |