38 / 68 page ![]() ADE7953 Data Sheet Rev. A | Page 38 of 68 POWER FACTOR The ADE7953 provides a direct power factor measurement simultaneously on Current Channel A and Current Channel B. Power factor in an ac circuit is defined as the ratio of the active power flowing to the load to the apparent power. The power factor measurement is defined in terms of “leading” or “lagging,” referring to whether the current waveform is leading or lagging the voltage waveform. When the current waveform is leading the voltage waveform, the load is capacitive and is defined as a negative power factor. When the current waveform is lagging the voltage waveform, the load is inductive and is defined as a positive power factor. The relationship of the current waveform to the voltage wave- form is illustrated in Figure 59. ACTIVE (–) REACTIVE (–) ACTIVE (+) REACTIVE (–) +60° = θ; PF = –0.5 I V I –60° = θ; PF = +0.5 ACTIVE (–) REACTIVE (+) ACTIVE (+) REACTIVE (+) CAPACITIVE LOAD: CURRENT LEADS VOLTAGE INDUCTIVE LOAD: CURRENT LAGS VOLTAGE Figure 59. Capacitive and Inductive Loads As shown in Figure 59, the reactive power measurement is negative when the load is capacitive and positive when the load is inductive. The sign of the reactive power can therefore be used to reflect the sign of the power factor. The mathematical definition of power factor is shown in Equation 37. Power Factor = (37) Power Apparent Power Active Power Reactive of Sign × ) ( The power factor measurement includes the effect of all harmonics over the 1.23 kHz bandwidth. The power factor readings are stored in two 16-bit, signed registers: PFA (Address 0x10A) for Current Channel A and PFB (Address 0x10B) for Current Channel B. These registers are signed, twos complement registers with the MSB indicating the polarity of the power factor. Each LSB of the PFx register equates to a weight of 2−15; therefore, the maximum register value of 0x7FFF corresponds to a power factor value of 1. The minimum register value of 0x8000 corresponds to a power factor of −1. By default, the instantaneous active and apparent power readings are used to calculate the power factor, and the register is updated at a rate of 6.99 kHz. The sign bit is taken from the instantaneous reactive energy measurement on each channel. USING THE LINE CYCLE ACCUMULATION MODE TO DETERMINE THE POWER FACTOR If a power factor measurement with more averaging is required, the ADE7953 can use the line cycle accumulation measurement on the active and apparent energies to determine the power factor (see the Active Energy Line Cycle Accumulation Mode section and the Apparent Energy Line Cycle Accumulation Mode section). This option provides a more stable power factor reading. To use the line cycle accumulation mode to determine the power factor, the ADE7953 must be configured as follows: • The PFMODE bit (Bit 3) must be set to 1 in the CONFIG register (Address 0x102). • The line cycle accumulation mode must be enabled on both the active and apparent energies by setting the xLWATT and xLVA bits to 1 in the LCYCMODE register (Address 0x004). When using line cycle accumulation to determine the power factor, the update rate of the power factor measurement is an integral number of half line cycles. The number of half line cycles is programmed in the LINECYC register (Address 0x101). For complete information about setting up the line cycle accumula- tion mode, see the Active Energy Line Cycle Accumulation Mode section and the Apparent Energy Line Cycle Accumulation Mode section. POWER FACTOR WITH NO-LOAD DETECTION The power factor measurement is affected by the no-load condition if no-load detection is enabled (see the No-Load Detection section). The following considerations apply only when no-load detection is enabled and a no-load condition occurs: • If the apparent energy no-load condition is true, the power factor measurement is set to 1 because it is assumed that there is no active or reactive power. • If the active energy no-load condition is true, the power factor measurement is set to 0 because it is assumed that the load is purely capacitive or inductive. • If the reactive energy no-load condition is true, the sign of the power factor is based on the sign of the active power. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |