24 / 68 page ![]() ADE7953 Data Sheet Rev. A | Page 24 of 68 ACTIVE POWER CALCULATION Power is defined as the rate of energy flow from the source to the load. It is defined as the product of the voltage and current waveforms. The resulting waveform is called the instantaneous power signal and is equal to the rate of energy flow at every instant of time. The unit of power is the watt or joules/sec. ) sin( 2 ωt V V(t) × × = (3) ) sin( 2 ωt I I(t) × × = (4) where: V is the rms voltage. I is the rms current. P(t) = V(t) × I(t) (5) P(t) = VI − VI × cos(2ωt) (6) The average power over an integral number of line cycles (n) is given by the expression in Equation 7. ∫ = = nT VI dt t P nT P 0 ) ( 1 (7) where: P is the active or real power. T is the line cycle period. The active power is equal to the dc component of the instanta- neous power signal (P(t) in Equation 5). The active power is therefore equal to VI. This relationship is used to calculate active power in the ADE7953. Figure 44 illustrates this concept. INSTANTANEOUS POWER SIGNAL INSTANTANEOUS ACTIVE POWER SIGNAL: VRMS × IRMS P(t) = VRMS × IRMS – VRMS × IRMS × cos(2ωt) VRMS × IRMS 0x0 0000 I(t) = √2 × IRMS × sin(ωt) V(t) = √2× VRMS × sin(ωt) Figure 44. Active Power Calculation The signal chain for the active power and energy calculations in the ADE7953 is shown in Figure 45. The instantaneous power signal P(t) is generated by multiplying the current and voltage signals. The dc component of the instantaneous power signal is then extracted by LPF2 (low-pass filter) to obtain the active power information. Because LFP2 does not have an ideal “brick wall” frequency response, the active power signal has some ripple associated with it. This ripple is sinusoidal and has a frequency equal to twice the line frequency. Because the ripple is sinusoidal in nature, it is removed when the active power signal is integrated to compute the active energy (see the Active Energy Calculation section). The ADE7953 computes the active power simultaneously on Current Channel A and Current Channel B and stores the resulting measurements in the AWATT (Address 0x212 and Address 0x312) and BWATT (Address 0x213 and Address 0x313) registers, respectively. With full-scale inputs, the expected reading in the AWATT and BWATT registers is approximately 4862401 LSBs (decimal). The active power measurements are taken over a bandwidth of 1.23 kHz and include the effects of any harmonics within that range. The active power registers are updated at a rate of 6.99 kHz and can be read using the waveform sampling mode (see the Instantaneous Powers and Waveform Sampling section). SIGN OF ACTIVE POWER CALCULATION The active power measurement in the ADE7953 is a signed calculation. If the phase differential between the current and voltage waveforms is more than 90°, the power is negative. Negative power indicates that energy is being injected back into the grid. The ACCMODE register (Address 0x201 and Address 0x301) includes two sign indication bits that show the sign of the active power of Current Channel A (APSIGN_A) and Current Channel B (APSIGN_B). See the Sign Indication section for more information. VGAIN CURRENT CHANNEL A OR B VOLTAGE CHANNEL HPF xIGAIN DIGITAL INTEGRATOR HPF 48 0 + + xWATTOS PHCALx INTERNAL ACCUMULATION FIXED INTERNAL THRESHOLD ACTIVE POWER SIGNAL AENERGYx 23 0 LPF2 xWGAIN Figure 45. Active Energy Signal Chain |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |