| 数据搜索系统,热门电子元器件搜索 |
|
RT5021 数据表(PDF) 39 Page - Richtek Technology Corporation |
|
|
|||||||||||||||||||||||||||||
RT5021 数据表(HTML) 39 Page - Richtek Technology Corporation |
|
39 / 67 page ![]() RT5021 39 DS5021-01 April 2013 www.richtek.com Copyright 2013 Richtek Technology Corporation. All rights reserved. is a registered trademark of Richtek Technology Corporation. © Suspend Mode When USUS = 1, the charger will enter Suspend Mode. In Suspend Mode, CHG pin is high impedance and IUSUS(MAX) < 300 μA. Charging Current Decision The charge current can be set according to the I2C register A8.ISETA [3:0] setting : RT5021 allows user to set the battery charge current level and the list as below. The default value is 0.5A. Code BAT Charge Current Code BAT Charge Current Code BAT Charge Current Code BAT Charge Current 0000 0.1A 0001 0.2A 0010 0.3A 0011 0.4A 0100 0.5A 0101 0.6A 0110 0.7A 0111 0.8A 1000 0.9A 1001 1A 1010 1.1A 1011 1.2A ISETA [3:0] 1100 1.2A 1101 1.2A 1110 1.2A 1111 1.2A α 1 Fault-Time Icharge Example : If the sensing battery temperature is hot or cold, the charge current will reduce to half charge current. So, the fault-time will increase to be double. JEITA Battery Temperature Standard CV regulation voltage will be changed in the following battery temperature ranges : 0 °C to 10°C and 45°C to 60°C. This function can be disabled by A9.VSETH and A9.VSETC. CC regulation current will be changed in the following battery temperature ranges : 0 °C to 10°C and 45°C to 60°C. This function can be disabled by A9.ISETH and A9.ISETC. Fault-Time During the fast charge phase, several events may increase the charging time. For example, the system load current may have activated the APPM loop which reduces the available charging current or the device has entered thermal regulation because the IC junction temperature has exceeded TREG. However, once the duration exceeds the fault-time, the CHG output pin will flash at approximately 4Hz to indicate a fault condition and the charge current will be reduced to about 1mA. There are four methods to release the Fault-time : Re-plug power Toggle EN Enter/exit suspend mode Remove Battery OVP The fault-time is inverse proportional to the charger current. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |