| 数据搜索系统,热门电子元器件搜索 |
|
STPD01 数据表(PDF) 21 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STPD01 数据表(HTML) 21 Page - STMicroelectronics |
|
21 / 43 page ![]() Protection Function INT pin STATUS Pon pin STATUS The device follows a soft-start procedure when the temperature is below 135 °C with default output voltage value. SCP (short-circuit protection) Active as soon as the device is in regulation (at the ends of the soft-start). The protection is triggered when the output voltage is under the SCP threshold and the Ipk threshold is detected. The device acts by suddenly switching off both HS and LS MOSFET. The device follows a soft-start procedure after 300 ms with default output voltage value. The VOUT bits (reg 0x00) and Ilim bits (reg 0x01) are reset. LOW HIGH IPK (inductor peak current) Active as soon as the device is enabled and PVIN/VCC voltage valid is present (above the UVLO level), even during the soft-start. The condition is checked cycle-bye-ycle on the high-side and triggered once the current cross the IPK threshold. The device reacts switching asynchronously (independent from oscillator frequency) between Ipk and Ivalley with a given slope, dependent on L and Cout. LOW HIGH 7.8.1 Overvoltage protection Overvoltage protection behaves in different ways depending on the state of the device. Case A) OV during Vout transition • In case an OV occurs during a Vout transition, the output voltage must be reset to 5 V (Vsafe). Therefore, the following process applies: OV event longer than deglitch time => REG 0x00 = 0x64 => after blanking time, the half-bridge is put in high impedance if the OV condition is still present. In case OV lasts less than deglitch time, the event is filtered. Case B) OV during steady-state • Case B1) Vout=5 V If OV event is detected, the half-bridge is just put in high impedance until the condition disappears. • Case B2) Vout different than 5 V The following process applies: OV event longer than deglitch time => REG 0x00 = 0x64 => after blanking time, the half-bridge is put in high impedance if the OV condition is still present. In case OV lasts less than deglitch time, the event is filtered. 7.9 Interrupt functionality The interrupt output is activated on the edge of the fault and is reset once the fault disappears. To keep track of the fault, the corresponding bit in the INT_LTCH register is set. Such interrupt management process allows multiple interrupt tracking. The I2C master reads the INT_LTCH register and optionally can read the INT_STAT to check if some fault is still active. 7.10 Switching frequency The STPD01 allows two possible programmable switching frequencies (by I2C): 500 kHz (default) and 750 kHz (reg 0x05 bit 2). STPD01 Interrupt functionality DS13473 - Rev 1 page 21/43 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |