| 数据搜索系统,热门电子元器件搜索 |
|
ADP1048WARQZ-R7 数据表(PDF) 35 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADP1048WARQZ-R7 数据表(HTML) 35 Page - Analog Devices |
|
35 / 82 page ![]() Data Sheet ADP1048W DATA TRANSFER Format Overview The PMBus slave follows the transfer protocol of the SMBus specification, which is based on the fundamental transfer protocol format of the Philips I2 C Bus Specification, dated January 2000. Data transfers are byte wide, lower byte first. Each byte is transmitted serially, most significant bit (MSB) first. A typical transfer is diagrammed in Figure 32. See the SMBus and I2C specifications for an in-depth discussion of the transfer protocols. Figure 32. Basic Data Transfer Figure 32 through Figure 39 use the following abbreviations: S = start condition Sr = repeated start condition P = stop condition R = read bit W = write bit A = acknowledge bit (0) A = acknowledge bit (1) “A” represents the ACK (acknowledge) bit. The ACK bit is typi- cally active low (Logic 0) if the transmitted byte is successfully received by a device. However, when the receiving device is the bus master, the acknowledge bit for the last byte read is a Logic 1, indicated by A. Command Overview Data transfer using the PMBus slave is established using PMBus commands. The PMBus specification requires that all PMBus commands start with a slave address with the RW bit cleared (set to 0), followed by the command code. All PMBus commands supported by the ADP1048W follow one of the protocol types shown in Figure 33 through Figure 39. The PMBus slave module also supports manufacturer-specific extended commands. These commands follow the same protocol as the standard PMBus commands. However, the command code consists of the following two bytes: • The command code extension, 0xFE • The extended command code, 0x00 to 0xFF Using the manufacturer-specific extended commands, the PMBus device manufacturer can add an additional 256 manufacturer-specific commands to its PMBus command set. Figure 33. Send Byte Protocol Figure 34. Write Byte Protocol Figure 35. Write Word Protocol Figure 36. Read Byte Protocol Figure 37. Read Word Protocol Figure 38. Block Write Protocol MASTER TO SLAVE SLAVE TO MASTER S P A A W 7-BIT SLAVE ADDRESS 8-BIT DATA S P A A W SLAVE ADDRESS COMMAND CODE MASTER TO SLAVE SLAVE TO MASTER A S P A A DATA BYTE W SLAVE ADDRESS COMMAND CODE MASTER TO SLAVE SLAVE TO MASTER A A COMMAND CODE A S P DATA BYTE LOW W SLAVE ADDRESS A DATA BYTE HIGH MASTER TO SLAVE SLAVE TO MASTER A S A A W SLAVE ADDRESS COMMAND CODE P R DATA BYTE Sr A SLAVE ADDRESS MASTER TO SLAVE SLAVE TO MASTER A A S A A W SLAVE ADDRESS COMMAND CODE P R Sr SLAVE ADDRESS MASTER TO SLAVE SLAVE TO MASTER DATA BYTE LOW DATA BYTE HIGH A A A S A A W SLAVE ADDRESS COMMAND CODE P A BYTE COUNT = N DATA BYTE 1 DATA BYTE N MASTER TO SLAVE SLAVE TO MASTER Rev. 0 | Page 35 of 82 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |