| 数据搜索系统,热门电子元器件搜索 |
|
AS3977 数据表(PDF) 26 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS3977 数据表(HTML) 26 Page - ams AG |
|
26 / 47 page ![]() www.austriamicrosystems.com/AS3977 Revision 3.6 26 - 47 AS3977 Data Sheet - A p p l i c a t i o n I n f o r m a t i o n Software Power Down Method. Lock Transmit Bit. When the Power Down Mode is left, the lock transmit bit (LT) is set high. The power amplifier can not be switched on as long as the bit is set to high. 9.3.2 Active Edge of CLK When the Power Down Mode is left, the level of CLK at the rising edge of ENABLE determines the active edge of CLK (CLK polarity). Once the CLK polarity is set, it stays unchanged until the next Power Down Mode is re-entered. 9.3.3 Active State The Active state is entered at the rising edge of ENABLE, which as well resets the Power Down timer. Possible previous states are Power Down Mode, Transmit state. DATAIO is set to SDI data input and the Interface expects a command control byte to configure the state-machine. The SDI state can be left by programming another state or by setting ENABLE low for more than 2 16 XTAL cycles (Power Down timer). 9.3.4 Transmit State The state is entered upon command. The transmit command byte defines in combination with the configuration registers the transmit configuration. The power amplifier (PA) will be activated on the subsequent sampling edge of CLK after receiving the command byte only if the lock transmit bit has been reset (0) by a previous SDI command. Here (only here) the baud rate and data generator counters are reset, i.e. if Transmit was interrupted by a SDI communication and is re-entered again (with active PA), the baud rate generator is kept synchronized with the previous transmitted string. DATAIO is set to TX data input. If during transmit a low power reset (LPR) occurs, the lock transmit bit is set high and hence the power amplifier is switched off. The state can be left at the falling edge of ENABLE, or increasing the Supply Voltage above the threshold and setting the register bit (LT) to zero. The control of the power amplifier is determined by the command byte (bit A4 and A5). Step Software Power Down Method 1 Set power Down Bit =1 and put ENABLE to LOW level 2 Power on reset complete with next xtal cycle State ENABLE LT Description Power Down Mode ↑ 1 LT is set to High All other states ↑ LT-1 LT is unchanged except the Supply voltage drops down below the threshold level State ENABLE CLK Description Power Down Mode ↑ 0 DATAIO is sampled at the falling edge of CLK Power Down Mode ↑ 1 DATAIO is sampled at the rising edge of CLK All other states ↑ X CLK behavior is unchanged Table 20. PA Control Modes State LT A4 A5 ENABLE Description All States 1 X X X PAON low Transmit 0 X X 1 PAON high on the subsequent sampling edge of CLK after receiving the command byte Transmit 0 0 0 ↓ PAON low at the falling edge of ENABLE Transmit 0 0 1 ↓ PAON low at the falling edge of ENABLE but synchronized with baud rate, DATAIO is latched Transmit 0 1 X ↓ PAON stays high, DATAIO is latched |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |