| 数据搜索系统,热门电子元器件搜索 |
|
ADN8834ACPZ-R2 数据表(PDF) 17 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADN8834ACPZ-R2 数据表(HTML) 17 Page - Analog Devices |
|
17 / 27 page ![]() Data Sheet ADN8834 Rev. B | Page 17 of 27 MAXIMUM TEC CURRENT LIMIT To protect the TEC, separate maximum TEC current limits in cooling and heating directions are set by applying a voltage combination at the ILIM pin. Using a Resistor Divider to Set the TEC Current Limit The internal current sink circuitry connected to ILIM draws a 40 µA current when the ADN8834 drives the TEC in a cooling direction, which allows a high cooling current. Use the following equations to calculate the maximum TEC currents: VILIM_HEATING = VREF × RC2/(RC1 +RC2) where VREF = 2.5 V. VILIM_COOLING= VILIM_HEATING + ISINK_ILIM × RC1||RC2 where ISINK_ILIM = 40 µA. CS COOLING ILIM COOLING MAX TEC R V I V 25 . 1 _ _ _ − = where RCS = 0.525 V/A. CS HEATING ILIM HEATING MAX TEC R V I _ _ _ V 25 . 1 − = VILIM_HEATING must not exceed 1.2 V and VILIM_COOLING must be more than 1.3 V to leave proper margins between the heating and the cooling modes. VDD 40µA ILIM COOLING ITEC + – TEC CURRENT LIMIT VREF RC1 RC2 SW OPEN = VILIMH SW CLOSED = VILIMC Figure 32. Using a Resistor Divider to Set the TEC Current Limit |
|
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |