| 数据搜索系统,热门电子元器件搜索 |
|
AD9511/PCB 数据表(PDF) 33 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9511/PCB 数据表(HTML) 33 Page - Analog Devices |
|
33 / 60 page ![]() AD9511 Rev. A | Page 33 of 60 or power-down. When the SYNCB function is selected, the FUNCTION pin does not act as either RESETB or PDB. PDB: 58h<6:5> = 11b The FUNCTION pin may also be programmed to work as an asynchronous full power-down, PDB. Even in this full power- down mode, there is still some residual VS current because some on-chip references continue to operate. In PDB mode, the FUNCTION pin is active low. The chip remains in a power- down state until PDB is returned to logic high. The chip returns to the settings programmed prior to the power-down. See the Chip Power-Down or Sleep Mode—PDB section for more details on what occurs during a PDB initiated power- down. DISTRIBUTION SECTION As previously mentioned, the AD9511 is partitioned into two operational sections: PLL and distribution. The PLL Section was discussed previously. If desired, the distribution section can be used separately from the PLL section. CLK1 AND CLK2 CLOCK INPUTS Either CLK1 or CLK2 may be selected as the input to the distribution section. The CLK1 input can be connected to drive the distribution section only. CLK1 is selected as the source for the distribution section by setting Register 45h<0> = 1. This is the power-up default state. CLK1 and CLK2 work for inputs up to 1600 MHz. The jitter performance is improved by a higher input slew rate. The input level should be between approximately 150 mV p-p to no more than 2 V p-p. Anything greater may result in turning on the protection diodes on the input pins, which could degrade the jitter performance. See Figure 35 for the CLK1 and CLK2 equivalent input circuit. These inputs are fully differential and self-biased. The signal should be ac-coupled using capacitors. If a single-ended input must be used, this can be accommodated by ac coupling to one side of the differential input only. The other side of the input should be bypassed to a quiet ac ground by a capacitor. The unselected clock input (CLK1 or CLK2) should be powered down to eliminate any possibility of unwanted crosstalk between the selected clock input and the unselected clock input. DIVIDERS Each of the five clock outputs of the AD9511 has its own divider. The divider can be bypassed to get an output at the same frequency as the input (1×). When a divider is bypassed, it is powered down to save power. All integer divide ratios from 1 to 32 may be selected. A divide ratio of 1 is selected by bypassing the divider. Each divider can be configured for divide ratio, phase, and duty cycle. The phase and duty cycle values that can be selected depend on the divide ratio that is chosen. Setting the Divide Ratio The divide ratio is determined by the values written via the SCP to the registers that control each individual output, OUT0 to OUT4. These are the even numbered registers beginning at 4Ah and going through 52h. Each of these registers is divided into bits that control the number of clock cycles the divider output stays high (high_cycles <3:0>) and the number of clock cycles the divider output stays low (low_cycles <7:4>). Each value is 4 bits and has the range of 0 to 15. The divide ratio is set by Divide Ratio = (high_cycles + 1) + (low_cycles + 1) Example 1: Set the Divide Ratio = 2 high_cycles = 0 low_cycles = 0 Divide Ratio = (0 + 1) + (0 + 1) = 2 Example 2: Set Divide Ratio = 8 high_cycles = 3 low_cycles = 3 Divide Ratio = (3 + 1) + (3 + 1) = 8 Note that a Divide Ratio of 8 may also be obtained by setting: high_cycles = 2 low_cycles = 4 Divide Ratio = (2 + 1) + (4 + 1) = 8 Although the second set of settings produce the same divide ratio, the resulting duty cycle is not the same. Setting the Duty Cycle The duty cycle and the divide ratio are related. Different divide ratios have different duty cycle options. For example, if Divide Ratio = 2, the only duty cycle possible is 50%. If the Divide Ratio = 4, the duty cycle may be 25%, 50%, or 75%. The duty cycle is set by Duty Cycle = (high_cycles + 1)/[(high_cycles + 1) + (low_cycles + 1)] See Table 17 for the values of the available duty cycles for each divide ratio. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |