| 数据搜索系统,热门电子元器件搜索 |
|
TAS5036APFCRG4 数据表(PDF) 22 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TAS5036APFCRG4 数据表(HTML) 22 Page - Texas Instruments |
|
22 / 62 page ![]() Architecture Overview 16 SLES061B—November 2002—Revised January 2004 TAS5036A Table 2−6. Device Outputs During Reset SIGNAL MODE SIGNAL STATE Valid 1−Valid 6 All Low PWM_P outputs All Low PWM_M outputs All Low MCLK_OUT All Low SCLK Master Low SCLK Slave Signal input LRCLK Master Low LRCLK Slave Signal input SDA All Signal input CLIP All High Because the RESET is an asynchronous control signal, small clicks and pops can be produced during the application (the leading edge) of this control. However, when RESET is released, the transition from the hard mute state back to normal operation is performed synchronously using a quiet sequence. If a completely quiet reset sequence is desired, MUTE should be applied before applying RESET. Table 2−7. Values Set During Reset CONTROL SETTING Volume 0 dB MCLK_IN frequency 256 Master/slave mode M_S terminal state Automute Enabled De-emphasis None DC offset 0 Interchannel delay Each channel is set to default value 2.2.2 Power Down—PDN The TAS5036A can be placed into the power-down mode by holding the PDN terminal low. When the power-down mode is entered, both the PLL and the oscillator are shut down. Volume is immediately set to full attenuation (there is no ramp down). The valid 1−6 outputs are immediately asserted low and the PWM outputs are placed in the hard mute state. PDN initiates device power down without clock inputs. As long as the PDN terminal is held low, the device is in the power-down (hard mute) state. During power down, all I2C and serial data bus operations are ignored. Table 2−8 shows the device output signals while PDN is active. Table 2−8. Device Outputs During Power Down SIGNAL MODE SIGNAL STATE Valid 1−Valid 6 All Low PWM_P outputs All Low PWM_M outputs All Low MCLK_OUT All Low SCLK Master Low SCLK Slave Signal input LRCLK Master Low LRCLK Slave Signal input SDA All Signal input CLIP All High To place the device in total power-down mode, both RESET and power-down modes must be enabled. Prior to bringing PDN high, RESET must be brought low for a minimum of 50 ns. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |