| 数据搜索系统,热门电子元器件搜索 |
|
SLAS366 数据表(PDF) 40 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
SLAS366 数据表(HTML) 40 Page - Texas Instruments |
|
40 / 58 page ![]() 5–4 5.6 DAC Path Digital Filter, fs = 8 kHz (see Note 4) 5.6.1 FIR Filter PARAMETER TEST CONDITIONS MIN TYP MAX UNIT 0 to 300 Hz –0.5 0.2 300 Hz to 3 kHz –0.25 0.25 Filter gain relati e to gain at 1020 H 3.3 kHz –0.35 0.3 dB Filter gain relative to gain at 1020 Hz 3.6 kHz –3 dB 4 kHz –40 ≥4.4 kHz –74 5.6.2 IIR Filter PARAMETER TEST CONDITIONS MIN TYP MAX UNIT 0 to 300 Hz –0.5 0.2 300 Hz to 3 kHz –0.25 0.25 Filter gain relative to gain at 1020 Hz 3.3 kHz –0.35 0.3 dB Filter gain relative to gain at 1020 Hz 3.6 kHz –3 dB 4 kHz –20 ≥4.4 kHz –60 NOTE 4: Filter gain outside of the bandpass is measured with respect to gain at 1020 Hz. The input signal is the digital equivalent of a sine wave (digital full scale = 0 dB). The nominal differential DAC channel output with this input condition is 4 VI(PP). The pass band is 0 Hz to 3600 Hz for an 8-kHz sample rate. This pass band scales linearly with the conversion rate. 5.7 DAC Dynamic Performance 5.7.1 OUTP/OUTM Signal-to-Noise When Load Is 600 Ω (see Note 5) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT VI = 0 dB 80 92 SNR Signal-to-noise ratio (SNR) VI = –9 dB 75 83 dB SNR Signal to noise ratio (SNR) VI = –40 dB 40 51 dB NOTE 5: Test condition is the digital equivalent of a 1020-Hz input signal with an 8-kHz conversion rate. The test is measured at the output of the application schematic low-pass filter. The test is conducted in 16-bit mode. 5.7.2 OUTP/OUTM Signal-to-Distortion When Load Is 600 Ω (see Note 5) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT VI = –0 dB 78 85 THD Total harmonic distortion VI = –9 dB 74 83 THD Total harmonic distortion VI = –40 dB 59 62 NOTE 5: Test condition is the digital equivalent of a 1020-Hz input signal with an 8-kHz conversion rate. The test is measured at the output of the application schematic low-pass filter. The test is conducted in 16-bit mode. 5.7.3 OUTP/OUTM Signal-to-Distortion + Noise When Load Is 600 Ω (see Note 5) PARAMETER TEST CONDITIONS MIN TYP MAX UNIT VI = –0 dB 75 82 Signal-to-total harmonic distortion + noise (THD + N) VI = –9 dB 70 77 dB Signal to total harmonic distortion + noise (THD + N) VI = –40 dB 34 44 dB NOTE 5: Test condition is the digital equivalent of a 1020-Hz input signal with an 8-kHz conversion rate. The test is measured at the output of the application schematic low-pass filter. The test is conducted in 16-bit mode. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |