AMC7832IPAPR 数据表(PDF) 33 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
AMC7832IPAPR 数据表(HTML) 33 Page - Texas Instruments |
|
33 / 74 page ![]() ALARM STATUS 0 0x70 RESERVED RESERVED RESERVED LV_ADC16 Alarm LV_ADC15 Alarm LV_ADC14 Alarm LV_ADC13 Alarm LV_ADC12 Alarm ALARM STATUS 1 0x71 RESERVED RESERVED RESERVED RESERVED ALARMIN Alarm Die Temperature Alarm Temp. Sensor High Alarm Temp. Sensor Low Alarm 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 GALR AMC7832 www.ti.com SLAS836 – MARCH 2014 8.3.2.4 Programmable Out-of-Range Alarms The AMC7832 is capable of continuously analyzing the 5 external unipolar inputs and internal temperature sensor conversion results for normal operation. Normal operation is established through the Lower and Upper Threshold registers (address 0x80 – 0x97). When any of the monitored inputs is out of the specified range, an alarm event is issued and the global alarm bit, GALR in the General Status register (0x72) is set. Details on the source of the alarm event can be determined through the Alarm Status registers (0x70 – 0x71). The ALARM-LATCH-DIS bit in the ALARMOUT Source 1 register (address 0x1D) sets the latching behavior for all alarms (except for the ALARMIN alarm which is always unlatched). When the ALARM-LATCH-DIS bit is cleared to ‘0’ the alarm bits in the Alarm Status registers are latched. The alarm bits are referred to as being latched because they remain set until read by software. This design ensures that out-of-limit events cannot be missed if the software is polling the device periodically. The alarm bits are cleared when their corresponding Alarm Status register is read, and are reasserted if the out-of limit condition still exists on the next monitoring cycle, unless otherwise noted. When the ALARM-LATCH-DIS bit is set to ‘1’, the alarm bits are not latched. The alarm bits in the Alarm Status registers go to '0' when the error condition subsides, regardless of whether the bit is read or not. Figure 47. AMC7832 Alarm Status Register All of the alarms can be set to activate the ALARMOUT terminal. The GPIO1/ALARMOUT terminal must be configured accordingly in the GPIO Configuration register (address 0x12) to enable this functionality. The ALARMOUT terminal works as an interrupt to the host so that it may query the Alarm Status registers to determine the alarm source. Any alarm event can activate the terminal as long as the alarm is not masked in the ALARMOUT Source registers (address 0x1C – 0x1D). When an alarm event is masked, the occurrence of the event sets the corresponding status bit in the Alarm Status registers to '1', but does not activate the ALARMOUT terminal. Copyright © 2014, Texas Instruments Incorporated Submit Documentation Feedback 33 Product Folder Links: AMC7832 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |