| 数据搜索系统,热门电子元器件搜索 |
|
AMC7832IPAPR 数据表(PDF) 46 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
AMC7832IPAPR 数据表(HTML) 46 Page - Texas Instruments |
|
46 / 74 page ![]() AMC7832 SLAS836 – MARCH 2014 www.ti.com Table 18. Register name: GPIO Configuration – Address: 0x12, Default: 0x00 (READ/WRITE) REGISTER DEFAULT ADDRESS BIT NAME DESCRIPTION NAME VALUE GPIO 0x12 7:5 Reserved Reserved for factory use 000 Config 4 Reserved Reserved for factory use 0 3 EN-DAV DAV terminal enable 0 0: GPIO3 operation (default) 1: DAV operation 2 EN-ADCTRIG ADCTRIG terminal enable 0 0: GPIO2 operation (default) 1: ADCTRIG operation 1 EN-ALARMOUT ALARMOUT terminal enable 0 0: GPIO1 operation (default) 1: ALARMOUT operation 0 EN-ALARMIN ALARMIN terminal enable 0 0: GPIO0 operation (default) 1: ALARMIN operation Table 19. Register name: ADC MUX Configuration 0 – Address: 0x13, Default: 0x00 (READ/WRITE) REGISTER DEFAULT ADDRESS BIT NAME DESCRIPTION NAME VALUE ADC MUX 0x13 7 CH7 When set to ‘1’ the corresponding analog input channel ADC_n is 0 Config 0 accessed during an ADC conversion cycle. 6 CH6 0 When cleared to ‘0’ the corresponding input channel ADC_n is 5 CH5 0 ignored during an ADC conversion cycle. 4 CH4 0 3 CH3 0 2 CH2 0 1 CH1 0 0 CH0 0 Table 20. Register name: ADC MUX Configuration 1 – Address: 0x14, Default: 0x00 (READ/WRITE) REGISTER DEFAULT ADDRESS BIT NAME DESCRIPTION NAME VALUE ADC MUX 0x14 7 CH15 When set to ‘1’ the corresponding analog input channel ADC_n is 0 Config 1 accessed during an ADC conversion cycle. 6 CH14 0 When cleared to ‘0’ the corresponding input channel ADC_n is 5 CH13 0 ignored during an ADC conversion cycle. 4 CH12 0 3 CH11 0 2 CH10 0 1 CH9 0 0 CH8 0 Table 21. Register name: ADC MUX Configuration 2 – Address: 0x15, Default: 0x00 (READ/WRITE) REGISTER DEFAULT ADDRESS BIT NAME DESCRIPTION NAME VALUE ADC MUX 0X15 7:2 Reserved Reserved for factory use All zeros Config 2 1 TEMP-CH When set to ‘1’ the local temperature sensor is enabled for ADC 0 conversion. When cleared to ‘0’ the local temperature sensor is ignored. 0 CH16 When set to ‘1’ the corresponding analog input channel ADC_n is 0 accessed during an ADC conversion cycle. When cleared to ‘0’ the corresponding input channel ADC_n is ignored during an ADC conversion cycle. 46 Submit Documentation Feedback Copyright © 2014, Texas Instruments Incorporated Product Folder Links: AMC7832 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |