90 / 212 page ![]() in ® 90/212 in input message Code: F7 Description: Input a message. The corresponding output is performed by an out, outword or outbyte instruction, and must specify a message of the same length. Areg is the unsigned length in bytes, Breg is a pointer to the channel and Creg is a pointer to where the message is to be stored. The process executing in will be descheduled if the channel is external or is not ready, and is rescheduled when the communication is complete. Definition: Synchronize, and input Aregunsigned bytes from channel Breg to address Creg Areg ′← undefined Breg ′← undefined Creg ′← undefined Error signals: Can cause InternalChannel or ExternalChannel trap to be signalled (if enabled) when the process is rescheduled after synchronization. Comments: Secondar y instruction. Instruction is a descheduling point. Instruction is interruptible. See also: out |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|