22 / 72 page ![]() Monitor channel The Monitor channel is used to write and read all STLC5411 internal registers. Protocol on the Monitor channel allows a bidirectional transfer of bytes between UID and a control unit with ac- knowledgement at each received byte. Bytes are transmitted on the Br output and received on the Bx input in the Monitor channel time slot. A write or read cycle is always constituted of two bytes.(see fig. 5). It is possible to operate several write or read cycles within a single monitor mes- sage. Note: Special format is used for EOC channel. Write cycle The format to write a message into the UID is: A7 A6 A5 A4 A3 A2 A1 A0 1st byte D7 D6 D5 D4 D3 D2 D1 D0 2nd byte A7-A1: A0: D7-D0: Register Address Write/Read back Indicator Register Content After the first byte is shifted in, Register address is decoded. A0 set low indicates a write cycle: the content of the following received byte has to be loaded into the addressed register. A0 set high indicates a read-back cycle request. the second byte content is not significative. STLC5411 will respond to the request by sending back a message with the register content associ- ated with its own address. It is then possible for the microprocessor to receive the required regis- ter content after several other pending messages. To avoid any loss of data, it is recommended to operate only one read-back request at a time. Note: Special format is used for EOC channel. Read cycle When UID has a register content to send to the controller, it send it on the monitor channel di- rectly. Note that the data to send can be the con- tent of a Register previously requested by the controller by means of a read-back request. The format of the message sent by the UID is: A7 A6 A5 A4 A3 A2 A1 A0 1st byte D7 D6 D5 D4 D3 D2 D1 D0 2nd byte A7-A1: A0: D7-D0: Register Address forced to 0 is spontaneous interrupt, forced to 1 if read- back Register Content Exchange Protocol STLC5411 validates a received byte if it is de- tected two consecutive times identical. (see fig. 5) The exchange protocol is identical for both direc- tions. The sender uses the E bit to indicate that it is sending a Monitor byte while the receiver uses A bit to acknowledge the received byte.When no message is transferred, E bit and A bit are forced to inactive state. A transmission is started by the sender (Transmit section of the Monitor channel protocol handler) by putting the E bit from inactive to active state and by sending the first byte on Monitor channel in the same frame. Transmission of a message is allowed only if A bit sent from the receiver has been set inactive for at least two consecutive frames. When the receiver is ready, it validates the incoming byte when received identical in two consecutive frames. Then, the receiver set A bit from the inactive to the active state (preacknowl- edgement) and maintain active at least in the fol- lowing frame (acknowledgement). If validation is not possible (two last bytes re- ceived are not identical) the receiver aborts the message by setting the A bit active for only a sin- gle frame.The second byte can be transmitted by the sender putting the E bit from the active to the inactive state and sending the second byte on the Monitor channel in the same frame . The E bit is set inactive for only one frame. If it remains inac- tive more than one frame, it is an end of mes- sage. The second byte may be transmitted only after receiving of the pre-acknowledgement of the previous byte . Each byte has to be transmitted at least in two consecutive frames. The receiver validates the current received byte as for the first one and then set the A bit in the next two frames first from the active state to the inactive state (pre-acknowledgement) and back to the active (acknowledgement). If the receiver can- not validates the received current byte (two bytes received not identical)it pre-acknowledges nor- mally but let the A bit in the inactive state in the next frame which indicates an abort request . If a message sent by the UID is aborted, the UID will send again the complete message until receiving of an acknowledgement . A message received by the UID can be acknowledged or aborted with flow Control. The most significant bit (MSB) of Monitor byte is sent first on the Monitor channel. E & A bits are active low and inactive state on Br is 5 V. When no byte is transmitted, Monitor channel time slot STLC5411 22/72 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |