34 / 72 page ![]() TEST FUNCTIONS Various test functions are provided for transmitted pulse waveform checking, power spectral density measurement and transmitter linearity. Three commands in TXACT register are provided. The associated test function is enabled as long as the command is not disabled by any other com- mand. SP1: (0010) Send Single Pulses+1, -1: +1, -1, pulses are transmitted consecutively onto the line, one pulse per frame. SP3: (1011) Send Single Pulses+3, -3: +3, -3, pulses are transmitted consecutively onto the line, one pulse per frame. RDT: (0011) Random Data Transmitted: Random data can be transmitted onto the line continously. B1, B2 and D channel transparency between the digital interface and the line is en- abled. When auto-mode is selected, two test inputs (TEST1, TEST2) are provided allowing the same test functions as described above but without the need of a microcontroller. See Table 6 for Test pins biasing. Table 6: Test Pins TEST1 TEST2 FUNCTIONS 1 1 Normal operation 1 0 Send Single Pulse ± 1 0 1 Random Data Transmitted 0 0 Send Single Pulse ± 3 TURNING ON AND OFF THE DEVICE STLC5411 contains an automatic sequencer for the complete control of the start-up activation se- quences. Interactions with an external control unit requires only Activate Request and Deactivate Request commands, with the option of inserting break-points in the sequence for additional exter- nal control allowing for instance easy building of a repetor application. Automatic control of act, uoa/sai and dea bits in the M4 bit positions is pro- vided, along with the specified 40 ms, 480 ms and 15 s timers used during the sequencing. Except the Power up and Power down control that is slightly different, the Activation/Deactiva- tion procedures are identical in GCI and Mi- crowire/DSI modes. Same command codes or in- dication codes are used. In Microwire and GCI mode, activation control is done by writing in the Activation Control Register TXACT and by read- ing the Activation Indication Register RXACT. For TXACT and RXACT access, MICROWIRE port is used in MICROWIRE mode and C/I channel (or MONITOR channel depending of CID bit in CR2 register) is used in GCI mode. In MICROWIRE mode, a primitive indication gen- erates first an interrupt requesting an action from the Microprocessor, in GCI mode the primitive In- dication is directly transmitted via C/I (or MONI- TOR channel). Power on initialization Following the initial application of power, STLC5411 enters the power down deactivated state in MICROWIRE mode or in GCI mode de- pending on the polarization of the MW input. All the internal circuits including the master oscil- lator are inactive and in a low power state except for the 10 kHz Tone signal detector. The line out- puts LO+/LO- are low impedance and all digital outputs are high impedance. All programmable registers and the activation controller are reset to their default value. GCI configuration is defined by means of the con- figuration pins M0, CONF1 and CONF2 when Power supply is turned on. For LT and NT1-2 equipments, GCI configuration should be completed by means of Control Regis- ter Programming. See Table 1 for configuration pins bias. Line activation request When UID is in the power down state and a 10kHz tone TN or TL is detected from the line. LSD and INT (MICROWIRE/DSI only) open drain outputs are forced to zero. In NT configuration , code LSD (0000) is loaded in the activation indication register RXACT. In LT configuration, code AP (1000) is loaded in the activation indication register RXACT. In Microwire/DSI these indications are sent onto CO at the following access even if the UID is still in power down mode. In GCI these indications are sent onto the C/I channel as soon as GCI clocks are available. LSD open drain output is set back in the high im- pedance state as soon as the UID is powered up. INT open drain output is set back in the high im- pedance state when CS input is detected at zero. Depending of the ACTAUT and PUPAUT bits in CR6 register, UID can powered up itself, also automatically to start the activation. For all auto mode configurations, on 10KHz tone reception, power up and activation procedure are full automatic, but in NT1 auto, UID waits the uoa bit from the line before to provide (or not) the cloks and primitives to the S device. Power up control Microwire/DSI: control instruction PUP in ACT STLC5411 34/72 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |