| 数据搜索系统,热门电子元器件搜索 |
|
STLC5411FN 数据表(PDF) 36 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
STLC5411FN 数据表(HTML) 36 Page - STMicroelectronics |
|
36 / 72 page ![]() ways to enter quiet mode: QM bit in CR6 register and QM primitive command to write in TXACT register; in this last case, any further primitive will clear quiet mode. AUTOMODE For all auto mode configurations, AIS pin allows a choice of line interface: 27 or 15mH for the trans- former and resistors line or device side. In NT1, the activation/deactivation state machine and the automatic power-up / power-down capa- bilities of the UID provide for a direct connection through GCI between UID and SID-GCI (ST 5421) without the need of an extra microcontroller (see figure 13b). LSD- pin of SID-GCI must be con- nected together to the Bx input pin of UID to ensure autonomous power-up/down control. Activation/De- activation commands and indications are trans- ferred from one device to the other by means of the C/I channel. Maintenance functions are automat- ically processed in UID. Therefore, there is not transfer of messages on the Monitor channel be- tween UID and SID-GCI. Please note that the 2B+D loop-back request at the S interface is pro- vided using the C/I channel code ARL and that there is not automatic processing of S and Q mes- sages in SID-GCI. In Repetor, the same advantages provide for a di- rect connection through GCI between both UID without the need of an extra microcontroller (see figure 13c). As for NT1, C/I channel transfers acti- vation/deactivation commands and indications. Maintenance functions are automatically proc- essed in UIDs, needing the transfer of eoc mes- sages, overhead bits and CRC fault detections. This is performed autonomously on the Monitor channel by sending when required messages in a regular format as already described.EOC mes- sages are transmitted according to Table 5; over- head bits in the M4 channel excluding (act, dea, uoa and sai) transferred transparently; spare overhead bits in M5 or M6 bit positions are also transferred transparently; febe and nebe bits are transmitted according to Figure10. COMMAND INDICATION (C/I) CODES Activation, deactivation and some special test functions can be initiated by the system by writ- ing in TXACT register. Any status change of the on-chip state machine is indicated to the system by the UID by setting a new code in the RXACT register. When GCI is selected, TXACT and RXACT registers are normally associated with the C/I channel (it is possible to associate them with the MONITOR channel thank to the CID bit in CR2 register). All commands and indications are coded on four bits: C1, C2, C3, C4. Codes are listed in Table 7. For each mode, a list of recog- nized commands and generated indications is given. Hereafter, you have a detailed description of the codes depending on mode selected. NT mode: Command 0000 (PUP): Power Up When in the power down state, PUP command powers up the device ready for a cold or a warm start. When GCI is selected with clocks as out- puts, PUP command is replaced by pulling low Bx input pin. 0001 (RES): Reset RES command resets UID ready for a cold start. Configuration registers are not changed. RES can be operated when the device is either powered up or down. If RES command is applied when the line is not fully deactivated, UID properly ends the activation before to come back in H1 state; In this case DP or EIU indication is returned (Auto mode configu- ration or not respectively). 0010 (SP1): Send Single Pulse +1 and -1 SP1 test command forces UID to send +1, -1, pulses to the line, one pulse per frame. 0011 (RDT): Random Data Transmitted RDT test command forces UID to send data with random equiprobable levels at 80 kbaud. 0100 (EIS): Error Indicate S Interface EIS command reports on the U line, a default on the S interface. 0101 (PDN): Power Down PDN command forces UID to power down state. It should normally be used after UID has been set in a known deactivated state, e.g. in an NT after a DI status indication has been reported. In GCI, C/I indication (DI) is sent twice on Br output before UID powers down. 0110 (UAI): U interface Activation Indicate UAI command is significant only when RR bit is set equal one in CR2 register or if NT-RR-AUTO auto-mode is selected. After the receiver has been super-frame synchronized, UAI command allows UID to send SN3 signal to the line. 0111 (QM): Quiet Mode In this mode, UID does not react to any line status change. UID can be powered up or down and ready for a cold start or a warm start. All configu- ration registers and coefficients remain un- changed. Quiet Mode is disabled by any other command. Note: Inside UID, an logical or is implemented with this QM primitive and the QM bit in CR6 reg- ister. 1000 (AR): Activation Request Beeing in the Power Up and deactivated state STLC5411 36/72 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |