43 / 61 page ![]() M41T82-M41T83 Clock operation Doc ID 12578 Rev 12 43/61 3.14.2 Backup mode In backup mode, the operation of the output circuit is as shown in Table 16. In backup mode, frequency test is disabled. Thus, the FT bit is a ‘don’t care’. ABE enables interrupts in backup. If it is 0, the output pin is a 1 regardless of the other bits. The pin is also a 1 when OUT is a 1 and no interrupts are enabled. When OUT is 0 and ABE is a 1, the pin is 0 regardless of the interrupts. Thus, in order to enable interrupts in backup mode, OUT must be a 1 and ABE must be a 1, and one or more of the interrupt enables must be a 1. Simultaneous interrupts Since more than one interrupt source can cause the IRQ1/FT/OUT pin to go low, more than one interrupt may be pending when the microprocessor services the interrupt. Therefore, the application software should read the flags register (0Fh) to discern which condition or conditions are causing the pin to be asserted. Also be aware that once a flag causes the pin to assert, other flags could subsequently also go true. Since the pin is already low due to the first, no additional output transition will occur. That is why the software must check the flags register. Example: If the watchdog is in use and the oscillator fail detect interrupt is enabled, and the watchdog times out, the IRQ1/FT/OUT pin will go low. If, in the intervening time before the processor services the interrupt, something disturbs the oscillator, such as a drop of moisture landing on the crystal pins, the OF bit will also be set. Thus, when the software services the interrupt, it must service both sources: it must re-initialize the watchdog and clear the OF bit in order to de-assert the IRQ1/FT/OUT pin. By reading the flags register, the software will know both flags were set and that both need service. Table 16. Priority for IRQ1/FT/OUT pin when operating in backup mode OUT(1) ABE(2) A1IE(3) + OFIE(4) Pin Comment x0 x 1 When ABE is 0, the pin is 1 regardless of OUT or the interrupt sources. 1x 0 1 When OUT is 1 and no interrupts are enabled, the pin is 1. (A1IE and OFIE are the only interrupts applicable in this mode). 01 x 0 When ABE is 1 and OUT is 0, OUT dominates and regardless of the interrupt sources. 11 1 IRQ When one or more interrupts are enabled, ABE is a 1, and OUT is a 1, the pin stays high until one of the interrupts is asserted. 1. OUT is bit 7 of register 08h (digital calibration). 2. ABE is bit 5 of register 0Ah (alarm 1, month). 3. A1IE is bit 7 of register 0Ah (alarm 1, month). 4. OFIE is bit 7 of register 09h (watchdog). |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |