| 数据搜索系统,热门电子元器件搜索 |
|
ADE7763ARSZ 数据表(PDF) 43 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADE7763ARSZ 数据表(HTML) 43 Page - Analog Devices |
|
43 / 56 page ![]() Data Sheet ADE7763 Rev. C | Page 43 of 56 Voltage rms compensation is done after the square root. VRMS = VRMS0 + VRMSOS (60) where: VRMS0 is the rms measurement without offset correction. VRMS is linear from full-scale to full-scale/20. To calibrate the offset, two VRMS measurements are required, for example, at Vnominal and Vnominal/10. Vnominal is set at half of the full-scale analog input range so that the smallest linear VRMS reading is at Vnominal/10. VRMSOS = 1 2 2 2 1 V V VRMS V VRMS V − × − × 1 (61) where VRMS1 and VRMS2 are rms register values without offset correction for input V1 and V2, respectively. If the range of the 12-bit, twos complement VRMSOS register is not enough, use the voltage channel offset register, CH2OS, to correct the VRMS offset. Current rms compensation is performed before the square root: IRMS2 = IRMS02 + 32768 × IRMSOS (62) where IRMS0 is the rms measurement without offset correction. The current rms calculation is linear from full scale to full scale/100. To calibrate this offset, two IRMS measurements are required, for example, at Ib and IMAX/50. IMAX is set at half of the full-scale analog input range so that the smallest linear IRMS reading is at IMAX/50. IRMSOS = 2 1 2 2 2 1 2 2 2 2 2 1 I I IRMS I IRMS I − × − × × 32768 1 (63) where IRMS1 and IRMS2 are rms register values without offset correction for input I1 and I2, respectively. Apparent Energy Apparent energy gain calibration is provided for both meter-to- meter gain adjustment and for setting the VAh/LSB constant. VAENERGY = + × × 12 2 1 1 VAGAIN VADIV VAENERGYinitial (64) VADIV is similar to the CFDEN for the watt-hour calibration. It should be the same across all meters and determines the VAh/LSB constant. VAGAIN is used to calibrate individual meters. Apparent energy gain calibration should be performed before rms offset correction to make the most efficient use of the current test points. Apparent energy gain and watt gain compensation require testing at Ib, while rms and watt offset correction require a lower test current. Apparent energy gain calibration can be done simultaneously with the watt-hour gain calibration using line cycle accumulation. In this case, LAENERGY and LVAENERGY, the line cycle accumulation apparent energy registers, are both read following the line cycle accumulation interrupt. Figure 78 shows a flowchart for calibrating active and apparent energy simultaneously. VAGAIN = INT × − 12 ) ( ) ( 2 1 nominal IB expected IB LVAENERGY LVAENERGY (65) LVAENERGYIB(expected) = INT × × × ) ( s/h 3600 s time on Accumulati constant LSB VAh I V B nominal (66) The accumulation time is determined from Equation 33, and the line period can be determined from the period register according to Equation 34. The VAh represented by the VAENERGY register is VAh = VAENERGY × VAh/LSB constant (67) The VAh/LSB constant can be verified using this equation: LVAENERGY s time on Accumulati VA constant LSB VAh 3600 ) ( × = (68) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |