33 / 170 page ![]() DocID027452 Rev 5 33/170 L9779WD Functional description 169 Smart reset circuit monitors VB over voltage and generates RST signal if the over voltage lasts more than tVBOV2. When over voltage lasts more than tVBOV1 and less than tVBOV2, RST is not asserted, but all drivers are switched off without losing any configuration. In both cases the flag VB_OV is latched and resets every Read Diag operation. When RST is asserted to reset the µC, also all logic will be reset except logic involved in reset management, power up management, and power down management units. As a consequence all flags are cleared except those set by the smart reset unit, all drivers are disabled except the low battery drivers, all configuration registers are cleared and OUT_DIS bit goes to 1. A more detailed description of the module under reset can be found in the next table. The Table 9 summaries also relations with other conditions that switch off drivers and regulator. Table 9. Internal reset Event RST pin driven low Logic under reset Logic not reset Power-up/down manager output Information FLAG Power down Yes Internal registers Interfaces drivers LB interfaces drivers LB internal registers MSC_act CAN & K-LINE & VRS Smart reset function Power-up/down manager MRD=OFF VDD5=OFF V3V3=OFF VTRACK1,2=OFF N/A Power latch +KEY_ON rising edge Yes For TNL Internal registers Interfaces drivers LB interfaces drivers LB internal registers MSC_act CAN & K-LINE & VRS Smart reset function Power-up/down manager MRD=ON VDD5=ON V3V3=ON VTRACK1,2=ON TNL_RST VDD5 under voltage t<THOLD Yes Internal registers Interfaces drivers MSC_act CAN & K-LINE & VRS LB interfaces drivers LB internal registers Smart reset function Power-up/down manager MRD=ON VDD5=ON V3V3=ON VTRACK1,2=ON CRK_RST VDD5 under voltage t>THOLD Yes Internal registers Interfaces drivers LB interfaces drivers LB internal registers MSC_act CAN & K-LINE & VRS Smart reset function Power-up/down manager MRD=ON VDD5=ON V3V3=ON VTRACK1,2=ON VDD5UV_ RST |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |