| 数据搜索系统,热门电子元器件搜索 |
|
L9779WD 数据表(PDF) 37 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9779WD 数据表(HTML) 37 Page - STMicroelectronics |
|
37 / 170 page ![]() DocID027452 Rev 5 37/170 L9779WD Functional description 169 6.4.2 VDD5_UV detection modes VDD5_UV on RST unmasked without enabling VDD5_UV on MSC-SDO Mode 1 is the default mode. A VDD5_UV event crates a reset of the whole system which has the advantage that no special undervoltage topics concerning system behavior has to be cared about. Disadvantage concerns requirements for being functional down to low Ubat. Masking VDD5_UV on RST without enabling VDD5_UV on MSC-SDO Advantage of this mode 2 is that the system remains fully functional even in a VDD5_UV condition. This is especially interesting for systems whose requirements are to be functional down to low Ubat. However it must be considered that also external components are still functional at low Ubat. In mode 2 a VDD_UV condition is only detected by polling the monitoring flag CRK_RST. Masking VDD5_UV on RST and enabling VDD5_UV output on MSC-SDO Advantage of this mode 3 compared to mode 2 is that a VDD5_UV event is detected fast as no software polling of MSC register flag is necessary. This might be useful for external functions who must be reset fast in case of a VDD_UV event. Advantage compared to mode 1 is that the µC is not reset and therefore VDD5_UV recovery can be performed faster. If a VDD5_UV event occurs, MSC-SDO will go to low level. SDO will keep low permanently even if VDD5 recovers. So it is guaranteed that even short VDD5_UV events are not missed. The VDD5_UV condition is detected due to a MSC-SDO low pulse longer than the length of an upstream frame. Upon detection the µC will have to go to its VDD5_UV handling routine. There the µC will at first have to disable output of VDD5_UV on SDO for re-enabling MSC communication and then start polling the CRK_RST flag to check if undervoltage condition has healed or not. When undervoltage condition has healed and CRK_RST flag is back to normal, recovery process can continue and the output of VDD5_UV on MSC-SDO is enabled again for fast detection of an eventual next VDD5_UV condition. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |