| 数据搜索系统,热门电子元器件搜索 |
|
BQ28550-R1 数据表(PDF) 19 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
BQ28550-R1 数据表(HTML) 19 Page - Texas Instruments |
|
19 / 42 page ![]() Not Recommended for New Designs bq28550-R1 www.ti.com SLUSAS4A – OCTOBER 2012 – REVISED SEPTEMBER 2014 The communication format and protocol complies with the SMBus. 7.6.3 Programming 7.6.3.1 General Purpose Input-Output 7.6.3.1.1 CFET Control The GPIO can be configured to provide a signal called Charge FET control (CFET) using firmware. This output controls external circuitry to change the state of the external CHG FET. A low signal on this pin in association with recommended external components turns OFF the CHG FET. A high output maintains or turns ON the CHG FET after a valid turn OFF activity. The state of the GPIO on power-up will be low until the system is initialized and an internal power supply is active. The CFET control bit is located in the Control status register. If this output is not used, then connect this pin to VREG externally. The following parameters can be programmed in firmware for monitoring and protection using CFET control circuitry, providing the limits are set within the boundaries of the hardware thresholds: • Cell Overvoltage Condition • Overcurrent Charging Condition • Overtemperature Charging Condition 7.6.3.1.2 ALERT Output Another option for the GPIO is to be configured as an ALERT output to indicate any one of the following fault conditions, and to provide an interrupt signal to the host microprocessor: • Overcurrent Charging Condition • Overcurrent Discharging Condition • Overtemperature Condition • Overvoltage Condition • Undervoltage Condition The threshold trigger for these conditions is set through firmware registers, with each fault condition to be selectable for detection. The output is an open drain output with an external pull-up (through a 3.3k resistor). The ALERT output can be reset after the fault condition is removed OR can be latched and reset only by the host MCU resetting the ALERT register value to zeroes. If this output is not used, then connect this pin to VREG externally. 7.6.4 Communications 7.6.4.1 Authentication The bq28550-R1 device can act as a SHA-1/HMAC authentication slave by using its internal engine. Refer to the Application Note SLUA359 for SHA-1/HMAC for information. By sending a 160-bit SHA-1 challenge message to the bq28550-R1 device, it causes the gauge to return a 160- bit digest, based upon the challenge message and a hidden, 128-bit plain-text authentication key. If this digest matches an identical one generated by a host or dedicated authentication master, and when operating on the same challenge message and using the same plain text keys, the authentication process is successful. 7.6.4.1.1 Key Programming (Data Flash Key) By default, the bq28550-R1 device contains a default plain-text authentication key of 0x0123456789ABCDEFFEDCBA9876543210. This default key is intended for development purposes. It should be changed to a secret key and the part immediately sealed before putting a pack into operation. Once written, a new plain-text key cannot be read again from the gas gauge while in SEALED mode. Once the bq28550-R1 device is FULL ACCESS, the authentication key can be changed from its default value by writing to the Authentication() Extended Data Command locations. A 0x00 is written to BlockDataControl() to enable the authentication data commands. The bq28550-R1 device is now prepared to receive the 16-byte plain- text key, which must begin at the command location 0x40 and ending at 0x4f. Once written, the key is accepted when a successful checksum for the key has been written to AuthenticateChecksum(). The gauge can then be SEALED again. Copyright © 2012–2014, Texas Instruments Incorporated Submit Documentation Feedback 19 Product Folder Links: bq28550-R1 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |