BQ28550-R1 数据表(PDF) 27 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
BQ28550-R1 数据表(HTML) 27 Page - Texas Instruments |
|
27 / 42 page ![]() Not Recommended for New Designs bq28550-R1 www.ti.com SLUSAS4A – OCTOBER 2012 – REVISED SEPTEMBER 2014 7.6.5.7.6.2.1 Flash Updates Data flash can only be updated if Voltage() ≥ Flash Update OK Voltage. Flash programming current can cause an increase in LDO dropout. The value of Flash Update OK Voltage should be selected so that the bq28550-R1 VCC voltage does not fall below its minimum of 2.4 V during flash write operations. 7.6.5.7.7 Manufacturer Information Blocks The bq28550-R1 device contains 96 bytes of user-programmable data flash storage: Manufacturer Info Block A, Manufacturer Info Block B, Manufacturer Info Block C. The method for accessing these memory locations is slightly different, depending on whether the device is in FULL ACCESS, UNSEALED, or SEALED mode. 7.6.5.7.8 Access Modes The bq28550-R1 device provides three security modes (FULL ACCESS, UNSEALED, and SEALED) that control data flash access permissions. Data flash refers to those data flash locations that are accessible to the user, as specified in Table 8. Table 8. Data Flash Access Security Mode SBS Commands Data Flash Device Programming Standard and Extended FULL ACCESS R/W Yes Commands R/W Standard and some Extended UNSEALED R/W No Commands R/W SEALED Standard Commands R/W None No 7.6.6 Charging and Charge Termination Indication 7.6.6.1 Detection Charge Termination For proper bq28550-R1 operation, the user must specify cell charging voltage. The default value for this variable is in the data flash Charging Voltage. The bq28550-R1 device detects charge termination when: The battery current drops below the Taper Current for two consecutive Current Taper Window time periods during charging AND battery voltage is equal to or higher than the Charging Voltage – Taper Voltage. Full Charge is set when the taper condition is met. 7.6.6.2 Charge Suspend The bq28550-R1 device suspends charging when: • Temperature < JT1, OR • Temperature > JT4 in CHARGE-SUSPEND mode, if the [CHGSUSP] bit in OperationConfiguration is set. This will set the charging current to zero and the charging voltage to zero in the Safety Status Register. Also, the CHG bit is reset in ControlStatus register. The bq28550-R1 device can indicate to resume charging if: • Temperature ≥ JT1 + Temp Hys, AND • Temperature ≤ JT3 – Temp Hys. On resuming, the bq28550-R1 device sets the CHG bit in the ControlStatus Register, and sets ChargingCurrent according to the appropriate charging mode entered. The bq28550-R1 device also leaves the charge-suspend mode when the battery is removed in removable battery mode ([NR] = 0). 7.6.6.3 MANUFACTURER ACCESS(): 0x00/0x01 Issuing a Control() command requires a subsequent 2-byte subcommand. These additional bytes specify the particular control function desired. The Control() command allows the system to control specific features of the bq28550-R1 device during normal operation, and additional features when the device is in an access mode (described in Table 9). Copyright © 2012–2014, Texas Instruments Incorporated Submit Documentation Feedback 27 Product Folder Links: bq28550-R1 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |