| 数据搜索系统,热门电子元器件搜索 |
|
BQ28550-R1 数据表(PDF) 10 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
BQ28550-R1 数据表(HTML) 10 Page - Texas Instruments |
|
10 / 42 page ![]() Not Recommended for New Designs bq28550-R1 SLUSAS4A – OCTOBER 2012 – REVISED SEPTEMBER 2014 www.ti.com 7 Detailed Description 7.1 Overview The bq28550-R1 gas gauge accurately predicts the battery capacity and other operational characteristics of a single Li-Ion based rechargeable cell, while it also provides a state-of-the-art protection function against short circuit, overcurrent, and overvoltage. It can be integrated by a system processor to provide cell information, such as state-of-charge (SOC), Remaining Capacity, and Full Charge Capacity (FCC). NOTE Formatting conventions in this document: Commands: Italics with parentheses and no breaking spaces; for example, RemainingCapacity() Data Flash: Italics, bold, and breaking spaces; for example, Design Capacity Register Bits and Flags: Brackets only; for example, [TDA] Data Flash Bits: Italic and bold; for example, [NR] Modes and States: All capitals; for example, SEALED mode 7.2 Data Acquisition 7.2.1 Cell Voltage The bq28550-R1 gas gauge samples the single cell voltage from the BAT input terminal. The cell voltage is sampled and updated every 1 s in normal mode. The VSS ground connection of the bq28550-R1 gas gauge should be connected to the negative terminal of the sense resistor. This will prevent any error in short circuit and overcurrent measurements across the external CHG and DSG FETs. 7.2.2 Charge Measurement The device samples the charge into and out of the single cell using a low value sense resistor. The resistor (typically 5 m Ω to 20 mΩ) is connected between SRP and SRN to form a differential input to an integrating ADC (Coulomb counter). Charge activity is detected when VSR = V(SRP) – V(SRN) is positive, and discharge activity is detected when VSR = V(SRP) – V(SRN) is negative. This data is integrated over a period of time, using an internal counter, and updates Remaining Capacity with charge and discharge amount every 1 s in normal mode. 7.2.3 Current Measurement The device has a FIFO buffer, which uses the last four Coulomb counter readings to calculate the current. The current is updated every 1 s in normal mode. 7.2.4 Temperature Measurement and the TS Input The bq28550-R1 gas gauge measures external temperature via the TS pin in order to supply battery temperature status information to the gas gauging algorithm and charger-control sections of the gauge. Alternatively, the gauge can also measure internal temperature via its on-chip temperature sensor. Refer to the Pack Configuration[TEMPS] control bit. Regardless of which sensor is used for measurement, a system processor can request the current battery temperature by calling the Temperature() function (see Data Commands for more information). The temperature information is updated every 1 s in normal mode. The bq28550-R1 external temperature sensing is optimized with the use of a high accuracy negative temperature coefficient (NTC) thermistor with R25 = 10 K Ω ± 1% and B25/85 = 3435 KΩ ± 1% (such as Semitec 103AT for measurement). The shows additional circuit information for connecting this thermistor to the bq28550-R1 gas gauge. 10 Submit Documentation Feedback Copyright © 2012–2014, Texas Instruments Incorporated Product Folder Links: bq28550-R1 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |