| 数据搜索系统,热门电子元器件搜索 |
|
BQ28550-R1 数据表(PDF) 25 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
BQ28550-R1 数据表(HTML) 25 Page - Texas Instruments |
|
25 / 42 page ![]() Not Recommended for New Designs bq28550-R1 www.ti.com SLUSAS4A – OCTOBER 2012 – REVISED SEPTEMBER 2014 Table 7. Standard Commands (continued) Name Command Code Min Value Max Value Default value Units Sealed Access DeviceName() 0x21 — — bq28550-R1 ASCII R/W DeviceChemistry() 0x22 — — LION ASCII R/W ManufacturerData() 0x23 — — — ASCII R/W Authenticate() 0x2f — — — ASCII R CellVoltage1() 0x3f 0 65535 — mV R Extended SBS Data Commands OperationStatus() 0x54 0x0000 0xffff — 0xf7f7 R ChargingStatus() 0x55 0x0000 0xffff — — R UnSealKey() 0x60 0x00000000 0xffffffff — — R/W FullAccessKey() 0x61 0x00000000 0xffffffff — — R/W AuthenKey0() 0x63 0x00000000 0xffffffff — — R/W AuthenKey1() 0x64 0x00000000 0xffffffff — — R/W AuthenKey2() 0x65 0x00000000 0xffffffff — — R/W AuthenKey3() 0x66 0x00000000 0xffffffff — — R/W ManufacturerInfo() 0x70 — — — ASCII R/W SenseResistor() 0x71 0 65535 — µ Ω R/W Temperature() 0x72 0x0000 0xffff — — R ManufacturerStatus() 0xB1 — — R 7.6.5.7.2 Run-Time-to-Empty Battery pack run-time-to-empty can be calculated using the following method—the host system reads and stores the following information during a discharge period and averages the data over a user-determined period of time: • The DSG bit of the BatteryStatus register is set to ensure DOUT terminal is high (ensure the system is in discharge mode). • AverageCurrent (mA) – Positive value = Charge Current – Negative value = Discharge Current – One minute rolling average of current value (the user can accumulate this time for improved granularity) • RemainingCapacity (mAh) Run-Time-to-Empty = RemainingCapacity (avg mAh) ÷ AverageCurrent (mA). This result will be in hours, and therefore to convert to minutes, divide the results by 60. 7.6.5.7.3 Charging Time To Full This is a read-only function that predicts the remaining time until battery reaches full charge in minutes based on Average Current(). The computation accounts for the taper current time extension from the linear TTF computation based on a fixed Average Current() rate of change of accumulation. A value of 65,535 indicates a battery is NOT being charged. 7.6.5.7.4 Remaining Capacity Alert To set a notification when battery capacity is below a pre-determined value, the user can set a Remaining Capacity alarm alert in the system side. The Remaining Capacity value determined by the bq28550-R1 device is compared to the user-selected value. If the Remaining Capacity value < the user-selected Remaining Capacity threshold, the host system should instruct the user on what action is needed. Copyright © 2012–2014, Texas Instruments Incorporated Submit Documentation Feedback 25 Product Folder Links: bq28550-R1 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |