| 数据搜索系统,热门电子元器件搜索 |
|
BQ28550-R1 数据表(PDF) 24 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
BQ28550-R1 数据表(HTML) 24 Page - Texas Instruments |
|
24 / 42 page ![]() Not Recommended for New Designs bq28550-R1 SLUSAS4A – OCTOBER 2012 – REVISED SEPTEMBER 2014 www.ti.com Table 6. Operational Modes (continued) Mode Enter Mode Exit Mode Comment SLEEP bit set = 1 in operation Change SLEEP bit = 0 OR register AND AverageCurrent AverageCurrent measurement > Sleep The data is measured every 20 s to SLEEP measured is equal to Sleep current current value OR Current detected is reduce current consumption. value. above the IWAKE setting. From SLEEP mode if the WAIT_FULLSLEEP wait is The system exits the FULLSLEEP The wait time to enter FULLSLEEP programmed, this is the time the mode if there are any communication FULLSLEEP from SLEEP is 1 s to 240 s with the system must be in SLEEP mode commands set on the bus to the default at 15 s. before it can go to FULLSLEEP device. mode. From FULLSLEEP mode, the system will go into HIBERNATE mode if the The system exits this mode is the load current decreases to the VCELL > programmed threshold, Enters hibernation if VCELL range is programmed value, OR load current is > programmed 2.4 V to 3 V with default at 2.55 V. HIBERNATION OR if the cell voltage falls below the threshold, The load current threshold range is 0 programmed value, OR communication activity on bus line, to 0.7 A with a default value of 8 mA. OR the host sets the command in OR host sets the command in MAC. MAC. From SLEEP mode, the system will Exit from this mode if there is bus In this mode, the VREG and DSG enter this mode if the VCELL < 2.4 V activity, FET are turned OFF and the system for a period longer than 24 ms and OR the load current detected is > SHUTDOWN will only wake up if the charger is the charger is not attached. The IWAKE , attached on the Pack+, Pack– system can also be put in OR the charger is connected to the terminals. SHUTDOWN mode through MAC. system. 7.6.5.7 Data Commands 7.6.5.7.1 Standard Data Commands The bq28550-R1 device uses the following Command Code. Data RAM is updated and read by the gauge only once per second. Standard commands are accessible in NORMAL operation mode. Table 7. Standard Commands Name Command Code Min Value Max Value Default value Units Sealed Access ManufacturerAccess() 0x00 0x0000 0xffff — — R/W BatteryMode() 0x03 0x0000 0xe383 — — R/W Temperature() 0x08 0 65535 — 0.1K R Voltage() 0x09 0 65535 — mV R Current() 0x0a –32768 32767 — mA R AverageCurrent() 0x0b –32768 32767 — mA R MaxError() 0x0c 0% 100% — R RelativeStateOfCharge() 0x0d 0% 100% — R mAh or 10 RemainingCapacity() 0x0f 0 65535 — R/W mWh FullChargeCapacity() 0x10 0 65535 7200 mA R ChargingCurrent() 0x14 0 65534 2500 mA R ChargingVoltage() 0x15 0 65534 12600 mV R BatteryStatus() 0x16 0x0000 0xdbff — — R CycleCount() 0x17 0 65535 0 — R/W DesignCapacity() 0x18 0 65535 7200 mAh R/W DesignVoltage() 0x18 0 65535 3600 mV R/W SpecificationInfo() 0x1a 0x0000 0xffff 0x0031 — R/W ManufactureDate() 0x1b — — 0 ASCII R/W SerialNumber() 0x1c 0x0000 0xffff 0x0001 — R/W ManufacturerName 0x20 — — Texas Inst ASCII R/W 24 Submit Documentation Feedback Copyright © 2012–2014, Texas Instruments Incorporated Product Folder Links: bq28550-R1 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |