| 数据搜索系统,热门电子元器件搜索 |
|
VT82C596 数据表(PDF) 72 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
VT82C596 数据表(HTML) 72 Page - List of Unclassifed Manufacturers |
|
72 / 96 page ![]() VT82C596B Revision 0.3 June 17, 1999 -66- Function 3 Registers - Power Management and SMBus 7HFKQRORJLHV ,QF :H &RQQHFW :H &RQQHFW System Management Bus I/O-Space Registers I/O Offset 00 – SMBus Host Status...............................RWC 7-5 Reserved ........................................ always reads 0 4 Failed Bus Transaction....................................RWC 0 SMBus interrupt not caused by failed bus transaction ..............................................default 1 SMBus interrupt caused by failed bus transaction. This bit may be set when the KILL bit (I/O Rx02[1]) is set and can be cleared by writing a 1 to this bit position. 3 Bus Collision .....................................................RWC 0 SMBus interrupt not caused by transaction collision ..................................................default 1 SMBus interrupt caused by transaction collision. This bit is only set by hardware and can be cleared by writing a 1 to this bit position. 2 Device Error .....................................................RWC 0 SMBus interrupt not caused by generation of an SMBus transaction error ....................default 1 SMBus interrupt caused by generation of an SMBus transaction error (illegal command field, unclaimed host-initiated cycle, or host device timeout). This bit is only set by hardware and can be cleared by writing a 1 to this bit position. 1 SMBus Interrupt..............................................RWC 0 SMBus interrupt not caused by host command completion..............................................default 1 SMBus interrupt caused by host command completion. This bit is only set by hardware and can be cleared by writing a 1 to this bit position. 0Host Busy ..........................................................RO 0 SMBus controller host interface is not processing a coimmand ..........................default 1 SMBus host controller is busy processing a coimmand. None of the other SMBus registers should be accessed if this bit is set. I/O Offset 01h – SMBus Slave Status........................... RWC 7-6 Reserved ........................................ always reads 0 5 Alert Status ..................................................... RWC 0 SMBus interrupt not caused by SMBALERT# signal .................................................... default 1 SMBus interrupt caused by SMBALERT# signal. This bit will be set only if the Alert Enable bit is set in the SMBus Slave Control Register at I/O Offset R08[3]. This bit is only set by hardware and can be cleared by writing a 1 to this bit position. 4 Shadow 2 Status............................................... RWC 0 SMBus interrupt not caused by address match to SMBus Shadow Address Port 2......... default 1 SMBus interrupt or resume event caused by slave cycle address match to SMBus Shadow Address Port 2. This bit is only set by hardware and can be cleared by writing a 1 to this bit position. 3 Shadow 1 Status............................................... RWC 0 SMBus interrupt not caused by address match to SMBus Shadow Address Port 1......... default 1 SMBus interrupt or resume event caused by slave cycle address match to SMBus Shadow Address Port 1. This bit is only set by hardware and can be cleared by writing a 1 to this bit position. 2 Slave Status ..................................................... RWC 0 SMBus interrupt not caused by slave event match .................................................... default 1 SMBus interrupt or resume event caused by slave cycle event match of the SMBus Slave Command Register at PCI Function 3 Configuration Offset 85h (command match) and the SMBus Slave Event Register at SMBus Base + Offset 0Ah (data event match). This bit is only set by hardware and can be cleared by writing a 1 to this bit position. 1 Reserved ........................................ always reads 0 0 Slave Busy ......................................................... RO 0 SMBus controller slave interface is not processing data ...................................... default 1 SMBus controller slave interface is busy receiving data. None of the other SMBus registers should be accessed if this bit is set. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |