| 数据搜索系统,热门电子元器件搜索 |
|
CS2000-CP 数据表(PDF) 15 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS2000-CP 数据表(HTML) 15 Page - Cirrus Logic |
|
15 / 37 page ![]() CS2000-CP DS761F3 15 5.1.2 Crystal Connections (XTI and XTO) An external crystal may be used to generate RefClk. To accomplish this, a 20 pF fundamental mode par- allel resonant crystal must be connected between the XTI and XTO pins as shown in Figure 12. As shown, nothing other than the crystal and its load capacitors should be connected to XTI and XTO. Please refer to the “AC Electrical Characteristics” on page 8 for the allowed crystal frequency range. 5.1.3 External Reference Clock (REF_CLK) For operation with an externally generated REF_CLK signal, XTI/REF_CLK should be connected to the reference clock source and XTO should be left unconnected or pulled low through a 47 k resistor to GND. 5.2 Frequency Reference Clock Input, CLK_IN The frequency reference clock input (CLK_IN) is used in Hybrid PLL Mode by the Digital PLL and Fractional- N Logic block to dynamically generate a fractional-N value for the Frequency Synthesizer (see “Hybrid An- alog-Digital PLL” on page 13). The Digital PLL first compares the CLK_IN frequency to the PLL output. The Fractional-N logic block then translates the desired ratio based off of CLK_IN to one based off of the internal timing reference clock (SysClk). This allows the low-jitter timing reference clock to be used as the clock which the Frequency Synthesizer multiplies while maintaining synchronicity with the frequency reference clock through the Digital PLL. The allowable frequency range for CLK_IN is found in the “AC Electrical Char- acteristics” on page 8. 5.2.1 CLK_IN Skipping Mode CLK_IN skipping mode allows the PLL to maintain lock even when the CLK_IN signal has missing pulses for up to 20 ms (tCS) at a time (see “AC Electrical Characteristics” on page 8 for specifications). CLK_IN skipping mode can only be used when the CLK_IN frequency is below 80 kHz and CLK_IN is reapplied within 20 ms of being removed. The ClkSkipEn bit enables this function. Regardless of the setting of the ClkSkipEn bit the PLL output will continue for 223 SysClk cycles (466 ms to 1048 ms) after CLK_IN is removed (see Figure 13). This is true as long as CLK_IN does not glitch or have an effective change in period as the clock source is removed, otherwise the PLL will interpret this as a change in frequency causing clock skipping and the 223 SysClk cycle time-out to be bypassed and the PLL to immediately unlock. If the prior conditions are met while CLK_IN is removed and 223 SysClk cycles pass, the PLL will unlock and the PLL_OUT state will be determined by the ClkOutUnl bit; See “PLL Clock Output” on page 23. If CLK_IN is re-applied after such time, the PLL will remain unlocked for the specified time listed in the “AC Electrical Characteristics” on page 8 after which lock will be acquired and the PLL XTI XTO 40 pF 40 pF Figure 12. External Component Requirements for Crystal Circuit |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |